EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Influence of Different Implant Abutment Connection Types on the Stress Distribution in Standard and Short Implants and the Peripheral Bone: A Three-dimensional Finite Element Analysis

Pallavi Kumari, Roma Goswami, Deepesh Saxena, Anshul Trivedi

Indian Journal of Dental Sciences · 2026-07 · 18 (3) · 136-142

DOI: 10.4103/ijds.ijds_153_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Dental Sciences, online erschienen am 14.07.2026. Verfasst von Pallavi Kumari und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Implant abutment connections, mainly external and internal, influenced stress distribution, with internal types like Morse taper and Cross fit offering better mechanical stability. Finite Element Analysis (FEA) helped evaluating such designs under load. This study employed three-dimensional (3D) FEA to evaluate and compare the stress distribution in internal hexagon, cross-fit, and friction-fit implant–abutment connections – across standard and short implants – and in the surrounding bone under both occlusal and oblique loading conditions. Materials and Methods: This study utilized 3D bone modeling and FEA to evaluate von Mises stress distribution around standard and short implants, as well as in the surrounding bone, under a 200 N occlusal load and a 100 N oblique load applied at a 45° angle. The peri-implant bone was modeled as homogeneous, isotropic, and linearly elastic, while the interface between bone and implant was represented as a nonlinear friction-based contact model (coefficient = 0.3). Models were created in SolidWorks and analyzed using ANSYS APDL. A refined polygonal mesh was used, with discretization validated by limiting peak stress variation to ≤5%. Results were expressed in megapascals and statistically analyzed to assess implant and bone stress behavior.

Results

This study’s von Mises stress analysis revealed that cross fit abutment connections consistently produced the lowest stress in both standard and short implants and their surrounding bone under 200 N occlusal and 100 N oblique (45°) loading. While internal hexagon connections showed the highest stress values, especially in short implants, statistical analysis (two-way ANOVA) showed no significant differences among abutment types in standard ( P = 0.210, 0.489) and short implants ( P = 0.414, 0.337). However, unpaired t -test analysis between loading types indicated significantly higher stress under oblique loads for implant structures ( P < 0.005), although no significant difference was noted in peripheral bone ( P = 0.297 for standard, P = 0.383 for short implants).

Discussion

According to the research, both the length of an implant and its abutment connection design impact how mechanical stress is distributed. Internal hexagon connections generated higher von Mises stress, particularly when subjected to angled (oblique) forces. While friction fit and cross fit designs resulted in better stress distribution, these variations were not statistically significant. Additionally, because they have less surface area, shorter implants experienced elevated stress levels internally and in the adjacent bone, which worsened under angled loads. Finite Element Analysis (FEA) supported the finding that oblique loads generally increase overall stress. Ultimately, however, the study found no statistically significant differences in the stress absorbed by the surrounding bone across various implant types and loading angles. This indicates that under normal functional use, neither the implant's length nor its connection design drastically impacts the stress on the peri-implant bone.

Conclusion

The study concluded that the configuration of the implant–abutment interface influences distribution of stress in both standard and short implants, as well as the surrounding bone, under various loading conditions. Internal hexagon connections tend to experience higher stress, particularly under oblique loads, whereas cross fit and friction fit designs provide a more favorable, although not statistically significant, stress distribution. Although short implants exhibited higher internal stress, the differences in bone stress between short and standard implants were not statistically significant.

Zitieren

APA

Kumari, P., Goswami, R., Saxena, D., & Trivedi, A. (2026). Influence of Different Implant Abutment Connection Types on the Stress Distribution in Standard and Short Implants and the Peripheral Bone: A Three-dimensional Finite Element Analysis. Indian Journal of Dental Sciences, 18(3), 136-142. https://doi.org/10.4103/ijds.ijds_153_25

Vancouver

Kumari P, Goswami R, Saxena D, Trivedi A. Influence of Different Implant Abutment Connection Types on the Stress Distribution in Standard and Short Implants and the Peripheral Bone: A Three-dimensional Finite Element Analysis. Indian Journal of Dental Sciences. 2026;18(3):136-142. doi:10.4103/ijds.ijds_153_25

BibTeX
@article{Kumari2026,
  author = {Kumari, Pallavi and Goswami, Roma and Saxena, Deepesh and Trivedi, Anshul},
  title = {Influence of Different Implant Abutment Connection Types on the Stress Distribution in Standard and Short Implants and the Peripheral Bone: A Three-dimensional Finite Element Analysis},
  journal = {Indian Journal of Dental Sciences},
  year = {2026},
  volume = {18},
  number = {3},
  pages = {136--142},
  doi = {10.4103/ijds.ijds_153_25}
}
Kostenlos starten →