Dimensional Stability and Retention Strength of Impressions to Custom Impression Trays Fabricated Using Conventional Method and Additive Technology - An In-vitro Study
Indian Journal of Dental Research · 2023
DOI: 10.4103/ijdr.ijdr_519_23 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Indian Journal of Dental Research, 2023. Verfasst von K Sangeetha Priyadarshini und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics and Crown & Bridge, SRM Kattankulathur Dental College and Hospital, Chengalpattu, Tamil Nadu, India. Hauptthemen laut MEDLINE: Dental Impression Technique, Dental Impression Materials. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
3D printing technology is replacing manual fabrication in all fields. 3D-printed impression trays should be assessed as they could replace conventional impression trays in the future.
Aim
In-vitro comparison and evaluation of the dimensional stability and retention strength of impressions to custom impression trays fabricated using conventional method and additive technology. Materials and Methods: A maxillary edentulous auto-polymerizing acrylic resin model served as the master model. Two moulds were prepared from the master model in order to obtain 12 casts. One cast was scanned for 3D printing digital light processing (DLP) and fused deposition modelling (FDM) 24 impression trays using polylactic acid (PLA). Twelve casts were used to fabricate light cure impression trays. Polyvinyl-siloxane impressions were made on the master model using 36 impression trays and 18 trays each were used to assess dimensional stability and retention strength.
Results
In dimensional stability analysis, one sample t -test revealed a statistically significant difference between each group and the master model followed by a one-way ANOVA. There were significant differences, but the difference was less with FDM trays ( P < 0.05). In retention strength analysis, one-way Analysis of variance (ANOVA) revealed statistically significant difference between each group and post-hoc test revealed specific difference, the highest with FDM trays ( P < 0.05).
Conclusion
Dimensional changes were observed at 30 minutes and 72 hours. Lesser dimensional changes were observed when impressions were made using FDM trays followed by DLP and light cure trays. The mean retention strength seen in descending order was FDM, followed by DLP and light cure trays. The best retention strength was noticed when impressions were made using FDM trays.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics and Crown & Bridge, SRM Kattankulathur Dental College and Hospital, Chengalpattu, Tamil Nadu, India.
- Department of Prosthodontics and Implantology, SRM Kattankulathur Dental College and Hospital, Chengalpattu, Tamil Nadu, India.
Zitieren
APA
Priyadarshini, K. S., Nandini, V. V., Marimuthu, R., & Lathief, J. (2023). Dimensional Stability and Retention Strength of Impressions to Custom Impression Trays Fabricated Using Conventional Method and Additive Technology - An In-vitro Study. Indian Journal of Dental Research. https://doi.org/10.4103/ijdr.ijdr_519_23
Vancouver
Priyadarshini KS, Nandini VV, Marimuthu R, Lathief J. Dimensional Stability and Retention Strength of Impressions to Custom Impression Trays Fabricated Using Conventional Method and Additive Technology - An In-vitro Study. Indian Journal of Dental Research. 2023. doi:10.4103/ijdr.ijdr_519_23
BibTeX
@article{Priyadarshini2023,
author = {Priyadarshini, K Sangeetha and Nandini, V Vidyashree and Marimuthu, Russia and Lathief, Jailance},
title = {Dimensional Stability and Retention Strength of Impressions to Custom Impression Trays Fabricated Using Conventional Method and Additive Technology - An In-vitro Study},
journal = {Indian Journal of Dental Research},
year = {2023},
doi = {10.4103/ijdr.ijdr_519_23}
}
EUVIMED