Trueness and precision of complete denture digital impression compared to conventional impression: an in vitro study
PeerJ · 2025
DOI: 10.7717/peerj.19075 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PeerJ, 2025. Verfasst von Yousif A Al-Dulaijan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia. Hauptthemen laut MEDLINE: Dental Impression Technique, Digital Technology, Dental Impression Materials, Printing, Three-Dimensional. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
This study aimed to compare the precision and trueness of digital impressions of the edentulous arch made with different scanners to conventional physical impressions.
Methods
A total of 40 impressions of a completely edentulous maxillary arch model ( n = 10) were made using different digital impressions with an extraoral scanner, E3 3Shape desktop scanner, as the reference scan, intraoral scanner (TRIOS IOS, and Medit IOS) and Vinyl Polysiloxane impressions (VPS) impression using a Computer-Aided Design and Computer-Aided Manufacturing (CAD-CAM) custom tray. The VPS impression was scanned with the desktop scanner to produce standard tessellation language (STL) files for comparison with the digital impressions made by the Desktop and intraoral scanners. The STL files were super-imposed to a desktop scan and to each other with the same group using Geomagic Control X Software to assess the trueness and precision, respectively. A t-test was conducted for statistical analysis with a significance level of 0.05.
Results
The overall trueness, Medit had the highest deviation compared to the VPS and TRIOS groups with a P value of 0.0013 and
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia.
- Division of Prosthodontics, School of Dentistry, University of Alabama-Birmingham, Birmingham, Alabama, United States.
ORCID-Profile: Yousif A Al-Dulaijan
Zitieren
APA
Al-Dulaijan, Y. A., Alalawi, H., Gad, M. M., Al-Qarni, F. D., Fouda, S. M., & Ellakany, P. (2025). Trueness and precision of complete denture digital impression compared to conventional impression: an in vitro study. PeerJ. https://doi.org/10.7717/peerj.19075
Vancouver
Al-Dulaijan YA, Alalawi H, Gad MM, Al-Qarni FD, Fouda SM, Ellakany P. Trueness and precision of complete denture digital impression compared to conventional impression: an in vitro study. PeerJ. 2025. doi:10.7717/peerj.19075
BibTeX
@article{AlDulaijan2025,
author = {Al-Dulaijan, Yousif A and Alalawi, Haidar and Gad, Mohammed M and Al-Qarni, Faisal D and Fouda, Shaimaa M and Ellakany, Passent},
title = {Trueness and precision of complete denture digital impression compared to conventional impression: an in vitro study},
journal = {PeerJ},
year = {2025},
doi = {10.7717/peerj.19075}
}