Quantification of Anterior Chamber Angle in North Indian Population Using Scheimpflug-based Corneal Tomographer
Indian Journal of Cataract and Refractive Surgery · 2024
DOI: 10.4103/icrs.icrs_15_24 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Cataract and Refractive Surgery, 2024. Verfasst von Jaya Kaushik und 4 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben.
Abstract (Originalsprache)
A BSTRACT Objectives: Primary angle closure glaucoma shows faster clinical progression as compared to open-angle glaucoma. Hence, its early diagnosis is crucial so that prophylactic peripheral iridotomy can be done. The current gold standard for anterior chamber angle (ACA) assessment is gonioscopy but is invasive and requires skilled operators, limiting its widespread use. The objective of this study is to evaluate Sirius + Scheimpflug tomographer as a screening method for the diagnosis of gonioscopically narrow ACA. Materials and Methods: A comparative cross-sectional analysis of ACA and related parameters among glaucoma patients using dual Scheimpflug analyzer Sirius + was done. Sirius + measurements were correlated with gonioscopically closed angle and open angles to determine statistical significance. This clinical study included 80 eyes of 40 patients reporting to the ophthalmology department with raised intraocular pressure.
Results
The mean ACA recorded for open-angle eyes was 39.05° ± 5.91° and was 25.92° ± 4.46° for narrow-angle eyes ( P < 0.0001). The Pearson correlation coefficient revealed a significant correlation of Sirius + parameters (ACA, anterior chamber volume [ACV], aqueous depth, horizontal anterior chamber diameter, and lens rise) with gonioscopically closed angles (Shaffer’s grade 2 or below) which was further confirmed by receiving operator characteristic analysis wherein areas under curve revealed excellent discriminant power of ACA, ACV, lens rise, and aqueous depth in detecting closed angles.
Conclusions
Scheimpflug-based tomography offers objective measurements, enhancing the reliability of ACA evaluation. The study employed the technology to quantify the ACA and highlighted the statistically significant Sirius + parameters that can be exercised for screening and early diagnosis for patients with angle closure glaucoma.
Zitieren
APA
Kaushik, J., Goyal, S., Singh, A., Gupta, S., & Parihar, J. K. S. (2024). Quantification of Anterior Chamber Angle in North Indian Population Using Scheimpflug-based Corneal Tomographer. Indian Journal of Cataract and Refractive Surgery. https://doi.org/10.4103/icrs.icrs_15_24
Vancouver
Kaushik J, Goyal S, Singh A, Gupta S, Parihar JKS. Quantification of Anterior Chamber Angle in North Indian Population Using Scheimpflug-based Corneal Tomographer. Indian Journal of Cataract and Refractive Surgery. 2024. doi:10.4103/icrs.icrs_15_24
BibTeX
@article{Kaushik2024,
author = {Kaushik, Jaya and Goyal, Sumit and Singh, Ankita and Gupta, Sandeep and Parihar, Jitendra Kumar Singh},
title = {Quantification of Anterior Chamber Angle in North Indian Population Using Scheimpflug-based Corneal Tomographer},
journal = {Indian Journal of Cataract and Refractive Surgery},
year = {2024},
doi = {10.4103/icrs.icrs_15_24}
}
EUVIMED