Feasibility and efficacy of endoscopic reintervention after covered metal stent placement for EUS-guided hepaticogastrostomy: A multicenter experience

Kosuke Minaga, Masayuki Kitano, Yoshito Uenoyama, Keiichi Hatamaru, Hideyuki Shiomi, Kenji Ikezawa, Tsukasa Miyagahara, Hajime Imai, Nao Fujimori, Hisakazu Matsumoto, Yuzo Shimokawa, Atsuhiro Masuda und 3 weitere

Endoscopic Ultrasound · 2022-11 · 11 (6) · 478-486

DOI: 10.4103/eus-d-22-00029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopic Ultrasound, online erschienen am 05.12.2022. Verfasst von Kosuke Minaga und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Although the use of a long metal stent is favored for EUS-guided hepaticogastrostomy (EUS-HGS) for the relief of malignant biliary obstruction (MBO), endoscopic reintervention (E-RI) at the time of recurrent biliary obstruction (RBO) is challenging due to a long intragastric portion. This study evaluated the feasibility and safety of E-RI after a long partially covered metal stent (L-PCMS) placement during EUS-HGS. Materials and Methods: We performed a multicenter retrospective study between January 2015 and December 2019 examining patients with MBO who underwent E-RI for RBO through the EUS-HGS route after the L-PCMS placement. Technical and clinical success rates, details of E-RI, adverse events (AEs), stent patency, and survival time were evaluated.

Results

Thirty-three patients at eight referral centers in Japan who underwent E-RI through the EUS-HGS route were enrolled. The location of MBO was distal in 54.5%. The median intragastric length of the L-PCMS was 5 cm. As the first E-RI attempt, E-RI via the distal end of the existing L-PCMS was successful in 60.6%. The overall technical and clinical success rates of E-RI were 100% and 81.8%, respectively. Liver abscess was noted in one patient. A proximal biliary stricture was associated with the clinical ineffectiveness of E-RI in multivariable analysis (odds ratio, 12.5, P = 0.04). The median survival and stent patency duration after E-RI were 140 and 394 days, respectively.

Conclusions

Our study findings suggest that E-RI for RBO after EUS-HGS with a L-PCMS is technically feasible and clinically effective, without any severe AEs, especially for patients with distal MBO.

Schlagwörter

Stichwörter der Autor:innen

EUSEUS-guided biliary drainagehepaticogastrostomymalignant biliary obstructionreintervention

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan.
  • Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan.
  • Department of Gastroenterology, Japan Red Cross Wakayama Medical Center, Wakayama, Japan.
  • Department of Internal Medicine, Division of Gastroenterology, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Department of Hepatobiliary and Pancreatic Oncology, Osaka International Cancer Institute, Osaka, Japan.
  • Department of Gastroenterology, Nakatsu Municipal Hospital, Nakatsu, Japan.

Zitieren

APA

Minaga, K., Kitano, M., Uenoyama, Y., Hatamaru, K., Shiomi, H., Ikezawa, K., Miyagahara, T., Imai, H., Fujimori, N., Matsumoto, H., Shimokawa, Y., Masuda, A., Takenaka, M., Kudo, M., & Chiba, Y. (2022). Feasibility and efficacy of endoscopic reintervention after covered metal stent placement for EUS-guided hepaticogastrostomy: A multicenter experience. Endoscopic Ultrasound, 11(6), 478-486. https://doi.org/10.4103/eus-d-22-00029

Vancouver

Minaga K, Kitano M, Uenoyama Y, Hatamaru K, Shiomi H, Ikezawa K, et al. Feasibility and efficacy of endoscopic reintervention after covered metal stent placement for EUS-guided hepaticogastrostomy: A multicenter experience. Endoscopic Ultrasound. 2022;11(6):478-486. doi:10.4103/eus-d-22-00029

BibTeX
@article{Minaga2022,
  author = {Minaga, Kosuke and Kitano, Masayuki and Uenoyama, Yoshito and Hatamaru, Keiichi and Shiomi, Hideyuki and Ikezawa, Kenji and Miyagahara, Tsukasa and Imai, Hajime and Fujimori, Nao and Matsumoto, Hisakazu and Shimokawa, Yuzo and Masuda, Atsuhiro and Takenaka, Mamoru and Kudo, Masatoshi and Chiba, Yasutaka},
  title = {Feasibility and efficacy of endoscopic reintervention after covered metal stent placement for EUS-guided hepaticogastrostomy: A multicenter experience},
  journal = {Endoscopic Ultrasound},
  year = {2022},
  volume = {11},
  number = {6},
  pages = {478--486},
  doi = {10.4103/eus-d-22-00029}
}
Kostenlos starten →