B2 puncture with forward-viewing EUS simplifies EUS-guided hepaticogastrostomy (with video)
Endoscopic Ultrasound · 2022-07 · 11 (4) · 319-324
DOI: 10.4103/eus-d-21-00154 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopic Ultrasound, 2022-07. Verfasst von Nozomi Okuno und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background and Objectives: EUS-guided hepaticogastrostomy (EUS-HGS) is in widespread use; however, there are few dedicated devices. The B2 route is technically easier than the B3 route for guidewire insertion, dilation, and stenting but if performed with conventional oblique-viewing (OV) EUS, B2 puncture can cause transesophageal puncture and severe adverse events. The aim of this study was to assess the efficacy of forward-viewing (FV) EUS, which we have developed to improve safety for B2 puncture in EUS-HGS (B2-EUS-HGS). Patients and Methods: This single-center retrospective study included 61 consecutive patients who underwent B2-EUS-HGS with FV between February 2020 and March 2021 at Aichi Cancer Center, Japan. The patients were prospectively enrolled, and clinical data were retrospectively collected for these 61 cases.
Results
The overall technical success rate of EUS-HGS was 98.3% (60/61). The rate of EUS-HGS with FV was 95.0% (58/61) after three cases converted to OV, and that of B2-EUS-HGS with FV was 88.5% (54/61). The early adverse event rate was 6.5% (4/61). There were no instances of transesophageal puncture. Median procedure time was 24 min (range, 8–70), and no patient required cautery dilation.
Conclusions
B2-EUS-HGS can be performed safely using FV, without transesophageal puncture, and supportability of the device is improved as FV is coaxial with the guidewire. FV was efficacious in B2-EUS-HGS, which shows promise for clinical application in the future.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
- Department of Endoscopy, Aichi Cancer Center Hospital, Nagoya, Japan.
Zitieren
APA
Okuno, N., Hara, K., Mizuno, N., Haba, S., Kuwahara, T., Kuraishi, Y., Tajika, M., Tanaka, T., Onishi, S., Yamada, K., Fumihara, D., Yanaidani, T., Ishikawa, S., Yamada, M., Yasuda, T., & Elshair, M. (2022). B2 puncture with forward-viewing EUS simplifies EUS-guided hepaticogastrostomy (with video). Endoscopic Ultrasound, 11(4), 319-324. https://doi.org/10.4103/eus-d-21-00154
Vancouver
Okuno N, Hara K, Mizuno N, Haba S, Kuwahara T, Kuraishi Y, et al. B2 puncture with forward-viewing EUS simplifies EUS-guided hepaticogastrostomy (with video). Endoscopic Ultrasound. 2022;11(4):319-324. doi:10.4103/eus-d-21-00154
BibTeX
@article{Okuno2022,
author = {Okuno, Nozomi and Hara, Kazuo and Mizuno, Nobumasa and Haba, Shin and Kuwahara, Takamichi and Kuraishi, Yasuhiro and Tajika, Masahiro and Tanaka, Tsutomu and Onishi, Sachiyo and Yamada, Keisaku and Fumihara, Daiki and Yanaidani, Takafumi and Ishikawa, Sho and Yamada, Masanori and Yasuda, Tsukasa and Elshair, Moaz},
title = {B2 puncture with forward-viewing EUS simplifies EUS-guided hepaticogastrostomy (with video)},
journal = {Endoscopic Ultrasound},
year = {2022},
volume = {11},
number = {4},
pages = {319--324},
doi = {10.4103/eus-d-21-00154}
}
EUVIMED