EUVIMEDEUVIMED entdecken
Crossref

On the way to standardisation of EUS-guided hepaticogastrostomy

B. Martínez-Moreno, G. López-Roldán, L. Guilabert, J. Martinez Sempere, C. Mangas, L. Company, F. Ruiz, J. R. Aparicio

Endoscopy · 01.04.2024 · 56 (S 02 S 02) · S106

DOI: 10.1055/s-0044-1782922 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.04.2024. Verfasst von B. Martínez-Moreno und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Fistula dilation is one of the key steps when performing EUS-guided hepaticogastrostomy (EUS-HG). Knowing whether there are differences between the existing tools used in EUS-HG dilation may reduce the complexity and adverse events (AEs) associated with this technique.

Methods

Retrospective study of all HG-EUS performed in a tertiary centre between 2017 and 2023. The procedure time, technical success clinical success and adverse events associated with different dilatation methods during EUS-HG were evaluated. Dilation methods used were: 4mm balloon dilator, 6F cystotome, filiform catheter (4/7F) or a combination of the previous.

Results

Thirty-four patients were included with a technical success rate of 31/34 (91.2%). Clinical success was 100% when technical success was achieved. Table 1 shows the methods used for fistula dilatation. There were 7 AE (20.6%), all early AE and none intra-procedurally. The duration of the procedure was 37.5 (±15.7) minutes. A filiform catheter was used in 18 cases and fistula creation was possible in 17 cases (94.4%). The use of a single method for fistula creation reduced procedure time: 44.24 (±17) vs 31.8 (±13.7) min, p=0.018, but not AE. The use of a filiform catheter alone or in combination with dilatation was associated with a significant reduction in the procedure time: 33.7±(15.3) vs 44.6 (±16.5) min, p=0.033, as was the rate of AE: 5. 9% vs 35.7%, p=0.036. However, the use of balloon dilatation was associated with a significantly longer duration:42.7 (16.4) vs 31.3 (14.9), and AE: 25% vs 9.1%, the latter without statistical significance.

Conclusions

The use of a filiform catheter reduces the time and AE associated with EUS-HG. Its use can be recommended over other methods of fistula dilatation in EUS-HG. Standardisation of complex procedures increases safety and allows their use to be extended to other centres. Publication History Article published online: 15 April 2024 © 2024. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Martínez-Moreno, B., López-Roldán, G., Guilabert, L., Sempere, J. M., Mangas, C., Company, L., Ruiz, F., & Aparicio, J. R. (2024). On the way to standardisation of EUS-guided hepaticogastrostomy. Endoscopy, 56(S 02 S 02), S106. https://doi.org/10.1055/s-0044-1782922

Vancouver

Martínez-Moreno B, López-Roldán G, Guilabert L, Sempere JM, Mangas C, Company L, et al. On the way to standardisation of EUS-guided hepaticogastrostomy. Endoscopy. 2024;56(S 02 S 02):S106. doi:10.1055/s-0044-1782922

BibTeX
@article{MartnezMoreno2024,
  author = {Martínez-Moreno, B. and López-Roldán, G. and Guilabert, L. and Sempere, J. Martinez and Mangas, C. and Company, L. and Ruiz, F. and Aparicio, J. R.},
  title = {On the way to standardisation of EUS-guided hepaticogastrostomy},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {S 02 S 02},
  pages = {S106},
  doi = {10.1055/s-0044-1782922}
}
Kostenlos starten →