EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of remaining dentin thickness in molars following different access cavity designs and biomechanical preparation – An in vitro study

Hardik C. Parupaliya, Rajvi D. Doctor, Shikha K. Kanodia, Anjali A. Patel, Saloni K. Kanodia, Nandina Navya Haritha

Endodontology · 2026-04 · 38 (2) · 219-226

DOI: 10.4103/endo.endo_11_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endodontology, online erschienen am 27.05.2026. Verfasst von Hardik C. Parupaliya und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The objective of this study was to evaluate the impact of two different access cavity designs and biomechanical preparation on the remaining dentinal thickness (RDT) in mandibular molar teeth utilizing a 3-dimensional cone beam computed tomography (CBCT) imaging approach.

Methods

A total of 60 fully formed mandibular first and second molars, with multiple roots, were carefully selected. Randomization of samples was divided into two groups, a conventional access preparation group (Group 1) and a conservative access preparation group (Group 2), each consisting of 30 teeth. The samples underwent a pre-CBCT scan at three specific regions: 2 mm above the cementoenamel junction (CEJ), at the CEJ, and 2 mm below the CEJ. This was done to quantify the overall thickness of dentin. For the control group, samples were obtained, and biomechanical preparation was performed using the ProTaper X2 file. Group 2 utilized CK microendodontic burs and a dental operating microscope (DOM) to access samples. Biomechanical preparation was performed using the TruNatomy Prime file. After the cleaning and shaping process, samples from both groups underwent a post-CBCT scan to measure the RDT.

Results

The average RDT was lower in Group 1 compared to Group 2. Group 2 had greater preservation of pericervical dentin (PCD). The statistical difference between the experimental groups was extremely significant ( P < 0.001).

Conclusion

This study demonstrates that conservative access using a DOM and TruNatomy files preserves more PCD than conventional access with ProTaper Next. CBCT analysis confirmed reduced dentin loss, supporting the advantages of minimally invasive techniques.

Zitieren

APA

Parupaliya, H. C., Doctor, R. D., Kanodia, S. K., Patel, A. A., Kanodia, S. K., & Haritha, N. N. (2026). Evaluation of remaining dentin thickness in molars following different access cavity designs and biomechanical preparation – An in vitro study. Endodontology, 38(2), 219-226. https://doi.org/10.4103/endo.endo_11_25

Vancouver

Parupaliya HC, Doctor RD, Kanodia SK, Patel AA, Kanodia SK, Haritha NN. Evaluation of remaining dentin thickness in molars following different access cavity designs and biomechanical preparation – An in vitro study. Endodontology. 2026;38(2):219-226. doi:10.4103/endo.endo_11_25

BibTeX
@article{Parupaliya2026,
  author = {Parupaliya, Hardik C. and Doctor, Rajvi D. and Kanodia, Shikha K. and Patel, Anjali A. and Kanodia, Saloni K. and Haritha, Nandina Navya},
  title = {Evaluation of remaining dentin thickness in molars following different access cavity designs and biomechanical preparation – An in vitro study},
  journal = {Endodontology},
  year = {2026},
  volume = {38},
  number = {2},
  pages = {219--226},
  doi = {10.4103/endo.endo_11_25}
}
Kostenlos starten →