Influence of Different Access Cavity Designs on the Microstrain Distribution in Mandibular Premolars and First Molars: An In Vitro Comparative Study
European Journal of Prosthodontics and Restorative Dentistry · 29.10.2026
DOI: 10.1922/ejprd.v34i4s.2307 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Prosthodontics and Restorative Dentistry, online erschienen am 29.10.2026. Verfasst von Mahmoud Y. Abou-Elnaga und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Endodontically treated teeth have a high risk of vertical root fractures due to the extensive dentin removal required by traditional endodontic cavities (TEC). To combat this, conservative endodontic cavities (CEC) are designed to pulp chamber roof and pericervical dentin preservation.
Objectives
This study aimed to evaluate the biomechanical impact of varying endodontic access cavity designs on the microstrain distribution within the coronal and cervical dentin of mandibular premolars and first molars utilizing digital moiré interferometry (DMI). Materials and Methods: Twelve intact human mandibular teeth (six premolars and six first molars) were subjected to physiological compressive loads of 10, 20, 30, 40, and 50 N. A repeated-measures design was utilized wherein each specimen served as its own control. High-resolution axial (U-field) DMI fringe patterns were recorded on the flattened mesial surface at three distinct stages: intact tooth (Control Group, CG), following CEC preparation, and following TEC preparation.
Results
The intact specimens (CG) demonstrated the lowest magnitude of microstrain across all loading intervals, exhibiting predominantly low tensile strain in the coronal dentin. The preparation of a CEC significantly altered the biomechanical response, inducing a transition to compressive coronal microstrain (p < 0.005). Enlargement to a TEC further exacerbated this coronal deformation, yielding the highest coronal compressive microstrain values (p < 0.0001). Across all experimental groups and loading intervals, the cervical dentin showed significantly greater compressive microstrain compared to the coronal area (p < 0.0001).
Conclusions
The preservation of the pulp chamber roof is critical for maintaining the biomechanical stability of posterior teeth. De-roofing the pulp chamber in both CEC and TEC preparations significantly increases coronal flexure and cervical compressive microstrain compared to intact teeth, with TEC preparations inducing the most severe coronal deformation.
Zitieren
APA
Abou-Elnaga, M. Y., Amo, M. K. A., Yousef, M. S., Shaban, A. G., Hagras, H. H., Khalaf, K. H. A., Refaei, M. A. A., Elsayed, H. M., & El-Aziz, M. E. A. A. (2026). Influence of Different Access Cavity Designs on the Microstrain Distribution in Mandibular Premolars and First Molars: An In Vitro Comparative Study. European Journal of Prosthodontics and Restorative Dentistry. https://doi.org/10.1922/ejprd.v34i4s.2307
Vancouver
Abou-Elnaga MY, Amo MKA, Yousef MS, Shaban AG, Hagras HH, Khalaf KHA, et al. Influence of Different Access Cavity Designs on the Microstrain Distribution in Mandibular Premolars and First Molars: An In Vitro Comparative Study. European Journal of Prosthodontics and Restorative Dentistry. 2026. doi:10.1922/ejprd.v34i4s.2307
BibTeX
@article{AbouElnaga2026,
author = {Abou-Elnaga, Mahmoud Y. and Amo, Mohamed K. Abo and Yousef, Mohamed Samir and Shaban, Ahmed Gamal and Hagras, Hossam Hazem and Khalaf, Karam Hamada Ahmed and Refaei, Mahmoud Abdellah Ahmed and Elsayed, Hosam Muhammed and El-Aziz, Mahmoud El-Said Ahmed Abd},
title = {Influence of Different Access Cavity Designs on the Microstrain Distribution in Mandibular Premolars and First Molars: An In Vitro Comparative Study},
journal = {European Journal of Prosthodontics and Restorative Dentistry},
year = {2026},
doi = {10.1922/ejprd.v34i4s.2307}
}
EUVIMED