Evaluation of intraocular lens power calculation in myopes using Barrett Universal II, SRK-T, and haigis formulae by optical biometry
Delta Journal of Ophthalmology · 2026-10 · 27 (4) · 267-273
DOI: 10.4103/djo.djo_24_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Delta Journal of Ophthalmology, online erschienen am 19.11.2026. Verfasst von Dina M.I. Abdou und 3 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
In cataract surgery, precise intraocular lens (IOL) power calculation is essential for obtaining the best possible refractive results, particularly in eyes with extreme myopia. The axial length (AL) is the most critical component in IOL power calculation.
Purpose
This study aimed to evaluate the accuracy of the Barrett Universal II (BU II) formula in IOL power calculation compared with the SRK-T and the Haigis formulae in myopic patients with AL of 26.0 mm or more using optical biometry. Patients and methods This prospective interventional case series involved 30 eyes of 28 high myopic individuals, with AL of 26 mm or more, who underwent uneventful phacoemulsification. One month after surgery, the postoperative refraction was recorded. The refractive prediction error (RPE) and mean absolute error of three IOL power calculation formulae (BU II, Haigis, and SRK-T) were examined and compared.
Results
The BU II formula had significantly the lowest mean RPE [0.175±0.423 diopters (D)], median absolute error (MedAE) (0.10 D), and proportion of eyes with hyperopic outcome (33.33%) compared to the Haigis and SRK-T formulae (mean RPE 0.534±0.450 and 0.536±0.514 D, respectively, MedAE 0.45 and 0.51 D, respectively, and percentage of hyperopic outcome 90 and 96.67%, respectively), ( P
Zitieren
APA
Abdou, D. M., Selima, A. A., Khater, M. M., & El-Marakby, O. O. (2026). Evaluation of intraocular lens power calculation in myopes using Barrett Universal II, SRK-T, and haigis formulae by optical biometry. Delta Journal of Ophthalmology, 27(4), 267-273. https://doi.org/10.4103/djo.djo_24_26
Vancouver
Abdou DM, Selima AA, Khater MM, El-Marakby OO. Evaluation of intraocular lens power calculation in myopes using Barrett Universal II, SRK-T, and haigis formulae by optical biometry. Delta Journal of Ophthalmology. 2026;27(4):267-273. doi:10.4103/djo.djo_24_26
BibTeX
@article{Abdou2026,
author = {Abdou, Dina M.I. and Selima, Adel A. and Khater, Mohamed M. and El-Marakby, Omnia O.},
title = {Evaluation of intraocular lens power calculation in myopes using Barrett Universal II, SRK-T, and haigis formulae by optical biometry},
journal = {Delta Journal of Ophthalmology},
year = {2026},
volume = {27},
number = {4},
pages = {267--273},
doi = {10.4103/djo.djo_24_26}
}
EUVIMED