EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation and Comparison of Marginal Adaptation of Computer-aided Design and Manufacturing Monolithic Polyether Ether Ketone and Zirconia Crown after 6 Months of Simulated Clinical Use: An In vitro Pilot Study

Ramanpreet Kaur, Veena Jain, Dheeraj Kumar Koli, Aditi Nanda, Tapas Chandra Nag

Contemporary Clinical Dentistry · 2026-04 · 17 (2) · 97-102

DOI: 10.4103/ccd.ccd_644_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contemporary Clinical Dentistry, online erschienen am 15.06.2026. Verfasst von Ramanpreet Kaur und 4 weiteren Autor:innen. Beteiligte Einrichtung: Oral Health Sciences Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Context

(Background): Marginal adaptation is a key determinant of the longevity and clinical success of fixed dental prostheses. Polyether ether ketone (PEEK), a high-performance polymer, has recently gained interest as an alternative to zirconia due to its favorable mechanical, esthetic, and biological properties.

Aims

To evaluate and compare the marginal adaptation of computer-aided design and manufacturing (CAD-CAM) monolithic PEEK and zirconia crowns cemented on natural teeth after simulating 6 months of clinical service. Settings and Design: An in vitro comparative pilot study was conducted using 28 extracted mandibular molars divided into two groups ( n = 14): Group I (PEEK) and Group II (Zirconia). Materials and Methods: Crowns were fabricated using CAD-CAM and cemented with self-adhesive resin cement. All specimens underwent thermocycling (120,000 cycles) and cyclic loading, followed by silver nitrate dye penetration. Sectioned specimens were examined under a scanning electron microscope (SEM) to assess vertical and horizontal marginal gaps. Statistical Analysis Used: Data were analyzed using SPSS v20. Normality was tested with the Shapiro–Wilk test, showing nonnormal distribution. The Mann–Whitney U test compared groups, with significance set at P < 0.05 (α = 0.05).

Results

Group I (PEEK) showed mean horizontal and vertical marginal gaps of 35.09 ± 16.79 μm and 32.71 ± 17.85 μm, respectively, while Group II (Zirconia) showed 25.88 ± 23.45 μm and 26.53 ± 8.69 μm. Differences were statistically insignificant ( P > 0.05).

Conclusions

Both PEEK and zirconia exhibited clinically acceptable marginal adaptation after simulated clinical aging. PEEK demonstrates comparable marginal accuracy to zirconia and can serve as a viable restorative alternative.

Schlagwörter

Stichwörter der Autor:innen

Fixed dental prosthesismarginal adaptationpolyether ether ketonescanning electron microscopezirconia

Autor:innen und Institutionen

  • Oral Health Sciences Centre, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Prosthodontics, Centre of Dental Education and Research, All India Institute of Medical Sciences, New Delhi, India.
  • Department of Anatomy, All India Institute of Medical Sciences, New Delhi, India.

Zitieren

APA

Kaur, R., Jain, V., Koli, D. K., Nanda, A., & Nag, T. C. (2026). Evaluation and Comparison of Marginal Adaptation of Computer-aided Design and Manufacturing Monolithic Polyether Ether Ketone and Zirconia Crown after 6 Months of Simulated Clinical Use: An In vitro Pilot Study. Contemporary Clinical Dentistry, 17(2), 97-102. https://doi.org/10.4103/ccd.ccd_644_25

Vancouver

Kaur R, Jain V, Koli DK, Nanda A, Nag TC. Evaluation and Comparison of Marginal Adaptation of Computer-aided Design and Manufacturing Monolithic Polyether Ether Ketone and Zirconia Crown after 6 Months of Simulated Clinical Use: An In vitro Pilot Study. Contemporary Clinical Dentistry. 2026;17(2):97-102. doi:10.4103/ccd.ccd_644_25

BibTeX
@article{Kaur2026,
  author = {Kaur, Ramanpreet and Jain, Veena and Koli, Dheeraj Kumar and Nanda, Aditi and Nag, Tapas Chandra},
  title = {Evaluation and Comparison of Marginal Adaptation of Computer-aided Design and Manufacturing Monolithic Polyether Ether Ketone and Zirconia Crown after 6 Months of Simulated Clinical Use: An In vitro Pilot Study},
  journal = {Contemporary Clinical Dentistry},
  year = {2026},
  volume = {17},
  number = {2},
  pages = {97--102},
  doi = {10.4103/ccd.ccd_644_25}
}
Kostenlos starten →