EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Polycaprolactone Resorbable Mesh versus Titanium Mesh for the Management of Orbital Floor Fracture: A Comparative Study

Vishesh Bhardwaj, K B Rithesh

Contemporary Clinical Dentistry · 2025-10 · 16 (4) · 243-252

DOI: 10.4103/ccd.ccd_457_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contemporary Clinical Dentistry, online erschienen am 26.12.2025. Verfasst von Vishesh Bhardwaj und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, A. J. Institute of Dental Sciences, Mangalore, Karnataka, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Orbital floor fractures are among the most common craniofacial injuries, often resulting from high-impact trauma such as motor vehicle accidents. Orbital floor fractures comprise 4%–16% of facial fractures and are of particular interest due to their unique anatomy and proximity to the eye. Treatment typically involves reconstruction with various materials as described in the literature.

Aim

The aim of the study was to evaluate the effectiveness of polycaprolactone (PCL) mesh in comparison to titanium mesh in the management of orbital floor fractures.

Methods

Twenty patients with clinically and radiographically confirmed orbital floor fractures were assigned to two groups: Group A (PCL mesh) and Group B (titanium mesh). Pre- and postoperative assessments included ocular motility, diplopia, dystopia, enophthalmos, infection, and implant stability. Follow-up evaluations were conducted on postoperative day 1, at 1 week, 1 month, and 3 months.

Results

PCL mesh demonstrated superior intraoperative handling, whereas adaptability and stability were similar between groups. Postoperatively, diplopia occurred in one patient (5%), dystopia in three patients (15%), and enophthalmos in five patients (25%), with no cases of infection, inflammatory response, implant migration, or hardware failure. All fractures achieved successful defect closure.

Conclusion

Both PCL and titanium meshes are effective for moderately sized orbital floor reconstructions. PCL mesh offers easier handling and is a viable alternative to titanium, though larger studies with longer follow-up are needed to confirm these findings.

Schlagwörter

Stichwörter der Autor:innen

Orbital floor fracturereconstructionresorbable meshtitanium meshtrauma

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery, A. J. Institute of Dental Sciences, Mangalore, Karnataka, India.

Zitieren

APA

Bhardwaj, V., & Rithesh, K. B. (2025). Polycaprolactone Resorbable Mesh versus Titanium Mesh for the Management of Orbital Floor Fracture: A Comparative Study. Contemporary Clinical Dentistry, 16(4), 243-252. https://doi.org/10.4103/ccd.ccd_457_25

Vancouver

Bhardwaj V, Rithesh KB. Polycaprolactone Resorbable Mesh versus Titanium Mesh for the Management of Orbital Floor Fracture: A Comparative Study. Contemporary Clinical Dentistry. 2025;16(4):243-252. doi:10.4103/ccd.ccd_457_25

BibTeX
@article{Bhardwaj2025,
  author = {Bhardwaj, Vishesh and Rithesh, K B},
  title = {Polycaprolactone Resorbable Mesh versus Titanium Mesh for the Management of Orbital Floor Fracture: A Comparative Study},
  journal = {Contemporary Clinical Dentistry},
  year = {2025},
  volume = {16},
  number = {4},
  pages = {243--252},
  doi = {10.4103/ccd.ccd_457_25}
}
Kostenlos starten →