A minimally invasive method for titanium mesh fixation with resorbable sutures in guided bone regeneration: A retrospective study
Clinical Implant Dentistry and Related Research · 2023-02 · 25 (1) · 87-98
DOI: 10.1111/cid.13147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Implant Dentistry and Related Research, online erschienen am 22.10.2022. Verfasst von Songhang Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Titanium, Dental Implants. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Exploration and R&D Project of West China Hospital of Stomatology, National Key R&D Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Objectives
Titanium mesh has become a mainstream choice for guided bone regeneration (GBR) owing to its excellent space maintenance. However, the traditional fixation method using titanium screws impacts surgery efficiency and increases patient trauma. We report a novel method of fixing a titanium mesh using resorbable sutures. We assessed the feasibility of resorbable sutures for fixing a titanium mesh and whether it can serve as a stable, universal, and minimally invasive fixation method for a broader application of titanium meshes.
Methods
Patients undergoing GBR with a digital titanium mesh fixed using titanium screws (TS group) and resorbable sutures (RS group) were observed at different time points. The stability of the fixation methods was evaluated on parameters such as titanium mesh spatial displacement, bone augmentation, and bone resorption.
Results
A total of 36 patients were included in this study. The exposure rate of the titanium mesh in the TS group was 16.67%, while no exposure was noted in the RS group. There was no significant difference in the parameters of titanium mesh spatial displacement, bone augmentation, and bone resorption between the two groups ( p > 0.05).
Conclusion
The use of resorbable sutures for fixing a titanium mesh can achieve similar results to traditional fixation using titanium screws. Although this new fixation method can improve the efficiency of the surgery and reduce the risk of complications, the long‐term clinical effects require further follow‐up investigation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
ORCID-Profile: Songhang Li, Xiaoxiao Cai
Förderung
- Exploration and R&D Project of West China Hospital of Stomatology
- National Key R&D Program of China
- National Natural Science Foundation of China
Zitieren
APA
Li, S., Zhao, Y., Tian, T., Zhang, T., Xie, Y., & Cai, X. (2023). A minimally invasive method for titanium mesh fixation with resorbable sutures in guided bone regeneration: A retrospective study. Clinical Implant Dentistry and Related Research, 25(1), 87-98. https://doi.org/10.1111/cid.13147
Vancouver
Li S, Zhao Y, Tian T, Zhang T, Xie Y, Cai X. A minimally invasive method for titanium mesh fixation with resorbable sutures in guided bone regeneration: A retrospective study. Clinical Implant Dentistry and Related Research. 2023;25(1):87-98. doi:10.1111/cid.13147
BibTeX
@article{Li2023,
author = {Li, Songhang and Zhao, Yuxuan and Tian, Taoran and Zhang, Tianxu and Xie, Yu and Cai, Xiaoxiao},
title = {A minimally invasive method for titanium mesh fixation with resorbable sutures in guided bone regeneration: A retrospective study},
journal = {Clinical Implant Dentistry and Related Research},
year = {2023},
volume = {25},
number = {1},
pages = {87--98},
doi = {10.1111/cid.13147}
}
EUVIMED