A Comparative Study in Airway Novices Using King Vision Videolaryngoscope and Conventional Macintosh Direct Laryngoscope for Endotracheal Intubation

Vinayak Seenappa Pujari, Balaji Thiyagarajan, Alagu Annamalai, Yatish Bevinaguddaiah, A C Manjunath, Leena Harshad Parate

Anesthesia Essays & Researches · 2021-01 · 15 (1) · 57-61

DOI: 10.4103/aer.aer_72_21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Anesthesia Essays & Researches, 2021-01. Verfasst von Vinayak Seenappa Pujari und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, MS Ramaiah Medical College, Ramaiah Teaching Hospital, Bengaluru, Karnataka, India. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives: Tracheal intubation using laryngoscopy is a fundamental skill, for an anesthesiologist. However, teaching this skill is difficult since Macintosh direct laryngoscope (DL) allows only one individual to view the larynx during the procedure. Hence, this study aimed to determine whether King Vision® videolaryngoscope (KVL) provides any advantage over direct laryngoscopy in teaching this skill to airway novices. Materials and Methods: In this prospective randomized crossover study, Ethical Committee clearance was obtained from the institutional review board (MSRMC/EC/2017) and the study was registered with Clinical Trial Registry. After informed consent, 53 medical students were allotted to perform laryngoscopy and endotracheal intubation on a manikin by using either KVL or Macintosh DL. The participants first performed laryngoscopy with either KVL or Macintosh DL following a brief instruction and then crossed over to the second arm of the study to perform laryngoscopy using the other scope. The primary outcome measure was the time for successful endotracheal intubation. The secondary outcome measures were incidence of esophageal intubation (EI), excess application of pressure on maxillary teeth excess maxillary pressure, and success rate.

Results

Mean time for endotracheal intubation was significantly faster using KVL than in DL (44.64 vs. 87.72 s; P < 0.001). No significant difference was found in the incidence of esophageal intubation 15.1% in KVL group versus 24.5% in DL group ( P = 0.223). In the KVL group, 81.1% did not apply pressure on maxillary teeth versus 26.4% in the DL group ( P < 0.001). The success rate of intubation was 100% in the KVL group versus 86.8% in the DL group ( P = 0.006).

Conclusion

The KVL is a more effective tool to teach endotracheal intubation in comparison to Macintosh laryngoscope in airway novice medical students. Clinical trial registry India registration number: CTRI/2017/11/010491.

Schlagwörter

Stichwörter der Autor:innen

Direct laryngoscopyKing Vision videolaryngoscopeMacintosh laryngoscopeendotracheal intubation

Autor:innen und Institutionen

  • Department of Anaesthesiology, MS Ramaiah Medical College, Ramaiah Teaching Hospital, Bengaluru, Karnataka, India.
  • Department of Anaesthesiology, Aster Al Raffah Hospital, Sohar, Oman.
  • Department of Anaesthesiology, SRM Medical College and Hospital, Tiruchirappalli, Tamil Nadu, India.

Zitieren

APA

Pujari, V. S., Thiyagarajan, B., Annamalai, A., Bevinaguddaiah, Y., Manjunath, A. C., & Parate, L. H. (2021). A Comparative Study in Airway Novices Using King Vision Videolaryngoscope and Conventional Macintosh Direct Laryngoscope for Endotracheal Intubation. Anesthesia Essays & Researches, 15(1), 57-61. https://doi.org/10.4103/aer.aer_72_21

Vancouver

Pujari VS, Thiyagarajan B, Annamalai A, Bevinaguddaiah Y, Manjunath AC, Parate LH. A Comparative Study in Airway Novices Using King Vision Videolaryngoscope and Conventional Macintosh Direct Laryngoscope for Endotracheal Intubation. Anesthesia Essays & Researches. 2021;15(1):57-61. doi:10.4103/aer.aer_72_21

BibTeX
@article{Pujari2021,
  author = {Pujari, Vinayak Seenappa and Thiyagarajan, Balaji and Annamalai, Alagu and Bevinaguddaiah, Yatish and Manjunath, A C and Parate, Leena Harshad},
  title = {A Comparative Study in Airway Novices Using King Vision Videolaryngoscope and Conventional Macintosh Direct Laryngoscope for Endotracheal Intubation},
  journal = {Anesthesia Essays & Researches},
  year = {2021},
  volume = {15},
  number = {1},
  pages = {57--61},
  doi = {10.4103/aer.aer_72_21}
}
Kostenlos starten →