EUVIMEDEUVIMED entdecken
Crossref

Comparison Of MAC Style Video Laryngoscope And Macintosh Laryngoscope For Endotracheal Intubation In A Simulated Difficult Airway: A Prospective Randomised Study

Dr. Praveen Kumar, Dr. Shiv Kumar Singh, Dr. Shivika Nath

IOSR Journal of Dental and Medical Sciences · 2026-05 · 25 (5) · 01-08

DOI: 10.9790/0853-2505040108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IOSR Journal of Dental and Medical Sciences, 2026-05. Verfasst von Dr. Praveen Kumar und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Endotracheal intubation remains a cornerstone of airway management. Direct laryngoscopy with the Macintosh blade can be compromised when anatomical alignment is restricted. MAC style video laryngoscopes retain familiar blade geometry and add an indirect view of the glottis. Limited data exist on their performance against the Macintosh in standardised models of difficult intubation.

Objectives

To compare laryngeal visualisation, intubation time, adjunct use, first attempt success, complications and ease of intubation between the MAC style video laryngoscope and the Macintosh laryngoscope in a simulated difficult airway.

Methods

This prospective randomised single blind study enrolled 110 adults (ASA I-II, age 18- 65 years) undergoing elective surgery under general anaesthesia at a single tertiary centre. A cervical collar simulated difficult airway conditions. Patients were randomised to intubation with a Macintosh laryngoscope (ML group, n = 55) or a MAC style video laryngoscope (MV group, n = 55). The primary outcome was Cormack-Lehane grade. Secondary outcomes included intubation time, bougie and external laryngeal manipulation use, first attemptsuccess, complications and ease of intubation.

Results

All 55 patients in the MV group achieved good laryngeal views (Cormack-Lehane grade I-II, 100%) versus 44 of 55 in the ML group (80.0%; p = 0.0006). Poor views (grade III-IV) occurred only in the ML group (20.0%). Mean intubation time wasshorter in the MV group (35.33 ± 6.59 s vs 41.99 ± 8.19 s; p < 0.0001). Bougie use (3.6% vs 21.8%; p = 0.008) and external laryngeal manipulation (18.2% vs 38.2%; p = 0.033) were less frequent with the video laryngoscope. First attempt success was comparable (94.5% vs 87.3%; p = 0.320). Complications were uncommon in both groups (3.6% vs 14.5%; p = 0.093). Intubation was rated easy in 89.1% of MV cases versus 54.5% in the ML group (p < 0.001).

Conclusion

The MAC style video laryngoscope provided superior laryngeal visualisation, shorter intubation times, reduced adjunct requirements and improved ease of intubation compared with the Macintosh laryngoscope in a simulated difficult airway. Both devices achieved high first attempt success and acceptable safety profiles.

Zitieren

APA

Kumar, D. P., Singh, D. S. K., & Nath, D. S. (2026). Comparison Of MAC Style Video Laryngoscope And Macintosh Laryngoscope For Endotracheal Intubation In A Simulated Difficult Airway: A Prospective Randomised Study. IOSR Journal of Dental and Medical Sciences, 25(5), 01-08. https://doi.org/10.9790/0853-2505040108

Vancouver

Kumar DP, Singh DSK, Nath DS. Comparison Of MAC Style Video Laryngoscope And Macintosh Laryngoscope For Endotracheal Intubation In A Simulated Difficult Airway: A Prospective Randomised Study. IOSR Journal of Dental and Medical Sciences. 2026;25(5):01-08. doi:10.9790/0853-2505040108

BibTeX
@article{Kumar2026,
  author = {Kumar, Dr. Praveen and Singh, Dr. Shiv Kumar and Nath, Dr. Shivika},
  title = {Comparison Of MAC Style Video Laryngoscope And Macintosh Laryngoscope For Endotracheal Intubation In A Simulated Difficult Airway: A Prospective Randomised Study},
  journal = {IOSR Journal of Dental and Medical Sciences},
  year = {2026},
  volume = {25},
  number = {5},
  pages = {01--08},
  doi = {10.9790/0853-2505040108}
}
Kostenlos starten →