Intraoperative Transesophageal Echocardiography Quantification of Mitral Regurgitation by Regurgitation Volume and Fraction Using 2D and 3D Techniques
Annals of Cardiac Anaesthesia · 2025
DOI: 10.4103/aca.aca_218_24 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Annals of Cardiac Anaesthesia, 2025. Verfasst von Devika Poduval und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Echocardiography, Transesophageal, Echocardiography, Three-Dimensional, Monitoring, Intraoperative. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Background and Aims: Intraoperative quantification of mitral regurgitation (MR) is sometimes necessary to quantify the severity of incidentally detected MR during cardiac surgeries. We aimed to compare and correlate the regurgitant volume (Rvol) and regurgitant fraction (RF) using 2D proximal isovelocity surface area (PISA) and 3D vena contracta area (VCA) with the 3D volumetric method and the integrated multiparametric approach. Methods and Materials: A prospective observational study was conducted on 37 patients undergoing mitral valve surgery for MR. Intraoperative quantification of the severity of MR was done using 2D PISA and 3D VCA methods and was compared with the 3D volumetric method. All three methods were compared with the integrated multiparametric method to obtain cutoff values for identifying severe MR.
Results
The correlation coefficients for Rvol with VCA and PISA with the 3D volumetric method were 0.688 and 0.58, respectively. VCA and PISA overestimated the Rvol (VCA = 77.93 ± 27.82 ml, PISA = 76.13 ± 19.25 ml) compared to the 3D volumetric method (66.12 ± 20.30 ml); the RF by the three methods was comparable. Using the receiver operating characteristic–area under curve (AUC) comparing Rvol by these methods with the integrated multiparametric method, the 3D volumetric method performed the best.
Conclusion
The Rvol VCA and PISA overestimated MR severity compared to the 3D volumetric method with moderate to good correlation. Rvol 3D was superior with a higher AUC when compared with the integrated multiparametric approach. The RF by the three methods was comparable, albeit with a higher threshold in quantifying severity compared to the conventional criteria.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Anaesthesia, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
- Department of Biostatistics, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
- Department of Cardiac Surgery, Amrita Institute of Medical Sciences, Kochi, Kerala, India.
Zitieren
APA
Poduval, D., Jose, R. L., Madathil, T., Nagarjuna, P., Kartha, N., Varma, P., & Neema, P. K. (2025). Intraoperative Transesophageal Echocardiography Quantification of Mitral Regurgitation by Regurgitation Volume and Fraction Using 2D and 3D Techniques. Annals of Cardiac Anaesthesia. https://doi.org/10.4103/aca.aca_218_24
Vancouver
Poduval D, Jose RL, Madathil T, Nagarjuna P, Kartha N, Varma P, et al. Intraoperative Transesophageal Echocardiography Quantification of Mitral Regurgitation by Regurgitation Volume and Fraction Using 2D and 3D Techniques. Annals of Cardiac Anaesthesia. 2025. doi:10.4103/aca.aca_218_24
BibTeX
@article{Poduval2025,
author = {Poduval, Devika and Jose, Reshmi L and Madathil, Thushara and Nagarjuna, P and Kartha, Niveditha and Varma, Praveen and Neema, Praveen Kumar},
title = {Intraoperative Transesophageal Echocardiography Quantification of Mitral Regurgitation by Regurgitation Volume and Fraction Using 2D and 3D Techniques},
journal = {Annals of Cardiac Anaesthesia},
year = {2025},
doi = {10.4103/aca.aca_218_24}
}
EUVIMED