EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY-NC-SA 4.0

Aortic Transvalvular Gradient Mis-Quantification

Marco Modestini, Jan A Krikken, Geertje Jansma, Wobbe Bouma, Jayant S Jainandunsing

Annals of Cardiac Anaesthesia · 2025

DOI: 10.4103/aca.aca_10_25 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Annals of Cardiac Anaesthesia, 2025. Verfasst von Marco Modestini und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University Medical Center Groningen, Groningen, The Netherlands. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Aortic Valve Stenosis, Aortic Valve. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mitral regurgitation (MR) can occasionally mimic aortic stenosis (AS) on echocardiographic Doppler imaging, leading to diagnostic challenges. We present the case of a 55-year-old man undergoing minimally invasive mitral valve surgery for severe MR caused by posterior mitral valve leaflet prolapse. Preoperative transthoracic echocardiography revealed severe MR with no significant aortic valve abnormalities. Intraoperative transesophageal echocardiography (TEE) initially showed a high transvalvular aortic gradient (3 m/s) in the transgastric long-axis view, suggestive of mild-to-moderate AS. However, detailed Doppler analysis revealed a double envelope signal, representing both eccentric MR and true aortic valve flow. The closer evaluation showed the MR signal occurred earlier in the cardiac cycle, aligning with its hemodynamic timing, while the true aortic flow followed isovolumetric contraction. Subsequent three-dimensional TEE confirmed normal aortic valve morphology and function. This case highlights the importance of correlating preoperative findings, Doppler signal timing, and imaging data to avoid misdiagnosis. Systematic echocardiographic evaluation, including signal timing analysis, can differentiate between MR and AS, ensuring accurate intraoperative decision-making and preventing unnecessary interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyAortic Valve StenosisAortic ValveHumansMaleMiddle AgedEchocardiography, TransesophagealMitral ValveEchocardiography

Stichwörter der Autor:innen

Doppler signal misinterpretationmitral regurgitationtransesophageal echocardiographytransthoracic echocardiography

Autor:innen und Institutionen

  • Department of Anesthesiology, University Medical Center Groningen, Groningen, The Netherlands.
  • Department of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
  • Department of Cardiothoracic Surgery, University Medical Center Groningen, Groningen, The Netherlands.

Zitieren

APA

Modestini, M., Krikken, J. A., Jansma, G., Bouma, W., & Jainandunsing, J. S. (2025). Aortic Transvalvular Gradient Mis-Quantification. Annals of Cardiac Anaesthesia. https://doi.org/10.4103/aca.aca_10_25

Vancouver

Modestini M, Krikken JA, Jansma G, Bouma W, Jainandunsing JS. Aortic Transvalvular Gradient Mis-Quantification. Annals of Cardiac Anaesthesia. 2025. doi:10.4103/aca.aca_10_25

BibTeX
@article{Modestini2025,
  author = {Modestini, Marco and Krikken, Jan A and Jansma, Geertje and Bouma, Wobbe and Jainandunsing, Jayant S},
  title = {Aortic Transvalvular Gradient Mis-Quantification},
  journal = {Annals of Cardiac Anaesthesia},
  year = {2025},
  doi = {10.4103/aca.aca_10_25}
}
Kostenlos starten →