Aim

This in vivo study was done to correlate the values of three different electronic apex locators: Root ZX, iPex, and Apex ID, with the radiographic working length (WL). Materials and Methods: Nineteen maxillary incisors with completely formed root apices indicated for endodontic treatment were chosen. After access preparation, coronal flaring and pulp extirpation, electronic measurement of WL was done with a No: 15 K file using the three devices on each tooth. A WL radiograph was then taken with the file placed within the canal and the length determined by following Ingle's method. The data were then analyzed using the correlation coefficient and Z -test.

Results

Root ZX showed the maximum correlation ( r = 0.9881) with radiographic WL followed by Apex ID ( R = 0.9731) and iPex ( R = 0.9508). Root ZX had a statistically significant higher correlation with radiographic WL in comparison with iPex ( P Conclusion: Maximum correlation of readings with the radiographic length was shown by Root ZX followed by Apex ID and then by iPex.

Zitieren

APA

Lekshmy, D., Deepthi, P., Ganesh, C., Chacko, G., Abhilash, A., Satheesh, S., Aravind, L., Nair, S., & Sreedhar, S. (2016). A comparative clinical study on the correlation of working length determined using three different electronic apex locators with radiographic working length: An in vivo study. Endodontology. https://doi.org/10.4103/0970-7212.184325

Vancouver

Lekshmy D, Deepthi P, Ganesh C, Chacko G, Abhilash A, Satheesh S, et al. A comparative clinical study on the correlation of working length determined using three different electronic apex locators with radiographic working length: An in vivo study. Endodontology. 2016. doi:10.4103/0970-7212.184325

BibTeX
@article{Lekshmy2016,
  author = {Lekshmy, DeviS and Deepthi, PR and Ganesh, C and Chacko, George and Abhilash, A and Satheesh, SL and Aravind, Lakshmi and Nair, SiddharthV and Sreedhar, Sreeja},
  title = {A comparative clinical study on the correlation of working length determined using three different electronic apex locators with radiographic working length: An in vivo study},
  journal = {Endodontology},
  year = {2016},
  doi = {10.4103/0970-7212.184325}
}
Kostenlos starten →