EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and reliability of an optometric isiZulu paediatric rate of reading test: A case study

Urvashni Nirghin, Rekha Hansraj, Lavanithum Joseph

African Vision and Eye Health · 14.01.2026 · 85 (1)

DOI: 10.4102/aveh.v85i1.1077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift African Vision and Eye Health, online erschienen am 14.01.2026. Verfasst von Urvashni Nirghin und 2 weiteren Autor:innen. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

IsiZulu is an official language in South Africa and the primary home language (HL) for many South African children. Currently, there are no optometric reading tests specific for isiZulu-speaking children.

Aim

This study aimed to develop and evaluate an isiZulu Paediatric Rate of Reading (PRR) Test for children, with or without visual impairment.

Setting

The study was conducted in primary schools of KwaZulu-Natal, South Africa, focusing on isiZulu-speaking primary school children.

Methods

The study followed a mixed-methods design. High-frequency isiZulu words from primary school textbooks were used to create six versions of the PRR Test, matching visual acuities from 1.0M to 4.0M. Reliability was tested on 162 isiZulu-speaking primary school children, conveniently selected from HL and First Additional Language (FAL) schools, whereby two examiners recorded results for reading performance over two sessions, one week apart.

Results

Bland-Altman plots indicated strong inter-rater agreement with paired t-tests showing no significant differences (P > 0.05) in inter-rater reading parameters. However, statistical differences (P < 0.05) for inter-session agreement were observed for the majority. Intraclass correlations for reading measures ranged from moderate to excellent (0.848–1.000).

Conclusion

The test showed good reliability for reading measures, except that reading error variation was observed. Contribution: This study contributes to the development of an isiZulu PRR Test, which is a reliable and linguistically relevant tool for assessing reading abilities in isiZulu-speaking children.

Zitieren

APA

Nirghin, U., Hansraj, R., & Joseph, L. (2026). Design and reliability of an optometric isiZulu paediatric rate of reading test: A case study. African Vision and Eye Health, 85(1). https://doi.org/10.4102/aveh.v85i1.1077

Vancouver

Nirghin U, Hansraj R, Joseph L. Design and reliability of an optometric isiZulu paediatric rate of reading test: A case study. African Vision and Eye Health. 2026;85(1). doi:10.4102/aveh.v85i1.1077

BibTeX
@article{Nirghin2026,
  author = {Nirghin, Urvashni and Hansraj, Rekha and Joseph, Lavanithum},
  title = {Design and reliability of an optometric isiZulu paediatric rate of reading test: A case study},
  journal = {African Vision and Eye Health},
  year = {2026},
  volume = {85},
  number = {1},
  doi = {10.4102/aveh.v85i1.1077}
}
Kostenlos starten →