The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study
Endoscopy · 2025-04 · 57 (04) · 312-320
DOI: 10.1055/a-2422-0856 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Endoscopy, online erschienen am 08.11.2024. Verfasst von Gianluca Esposito und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical-Surgical Sciences and Translational Medicine, Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy. Hauptthemen laut MEDLINE: Gastroscopy. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
Mucosal visualization during upper gastrointestinal (UGI) endoscopy can be impaired by the presence of foam, bubbles, and mucus. Some UGI endoscopy visibility scales have been proposed but have not undergone multicenter validation. This study aimed to develop and validate the Gastroscopy RAte of Cleanliness Evaluation (GRACE) scale.
Methods
A multicenter, international, cross-sectional study was conducted. The GRACE scale is based on a score from 0 (worst) to 3 (excellent) for esophagus, stomach, and duodenum, for a total ranging from 0 to 9. In phase 1, four expert endoscopists evaluated 60 images twice, with a 2-week interval between rounds; in phase 2, the same 60 images were scored twice by one expert and one nonexpert endoscopist from 27 endoscopy departments worldwide. For reproducibility assessment and real-time validation, the scale was applied to consecutive patients undergoing gastroscopy at each center.
Results
On internal validation, interobserver agreement was 0.81 (95 %CI 0.73–0.87) and 0.80 (95 %CI 0.72–0.86), with reliability of 0.73 (95 %CI 0.63–0.82) and 0.72 (95 %CI 0.63–0.81), in the two rounds, respectively. On external validation, overall interobserver agreement was 0.85 (95 %CI 0.82–0.88) and reliability was 0.79 (95 %CI 0.73–0.84). In real-time evaluation, the overall proportion of correct classifications was 0.80 (95 %CI 0.77–0.82).
Conclusions
The GRACE scale showed good interobserver agreement, reliability, and validity. The widespread use of this scale could enhance quality and standardize the assessment of mucosal cleanliness during UGI endoscopy, pushing endoscopists to strive for excellent visibility and reducing the risk of missed lesions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical-Surgical Sciences and Translational Medicine, Sant'Andrea Hospital, Sapienza University of Rome, Rome, Italy.
- Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine of the University of Porto, Porto, Portugal.
- Center for Health Technology and Services Research - CINTESIS@RISE, Faculty of Medicine of the University of Porto, Porto, Portugal.
- Gastroenterology Department, Portuguese Oncology Institute of Porto, Porto, Portugal.
- Center for Research in Health Technologies and Information Systems (CINTESIS), Faculty of Medicine, University of Porto, Porto, Portugal.
- Francisco Gentil Portuguese Institute for Oncology of Coimbra, Gastroenterology Department, Portuguese Oncology Institute of Coimbra (IPO Coimbra), Coimbra, Portugal.
ORCID-Profile: Gianluca Esposito, Miguel Areia
Zitieren
APA
Esposito, G., Dilaghi, E., Costa-Santos, C., Ligato, I., Annibale, B., Dinis-Ribeiro, M., Areia, M., & GRACE Investigators (2025). The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study. Endoscopy, 57(04), 312-320. https://doi.org/10.1055/a-2422-0856
Vancouver
Esposito G, Dilaghi E, Costa-Santos C, Ligato I, Annibale B, Dinis-Ribeiro M, et al. The Gastroscopy RAte of Cleanliness Evaluation (GRACE) Scale: an international reliability and validation study. Endoscopy. 2025;57(04):312-320. doi:10.1055/a-2422-0856
BibTeX
@article{Esposito2025,
author = {Esposito, Gianluca and Dilaghi, Emanuele and Costa-Santos, Cristina and Ligato, Irene and Annibale, Bruno and Dinis-Ribeiro, Mário and Areia, Miguel and GRACE Investigators, GRACE Investigators},