EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Additional yield of transbronchial cryo‐node biopsy over endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal lesions at a tertiary care center in India (COLD-FORCEPS-2 study)

Manu Madan, Rohit Kumar, Pranav Ish, Yash Kedia iD, A J Mahendran, Rajnish Kaushik, Neeraj Kumar Gupta, Nitesh Gupta

Monaldi Archives for Chest Disease · 2024

DOI: 10.4081/monaldi.2024.3054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Monaldi Archives for Chest Disease, 2024. Verfasst von Manu Madan und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pulmonary, Critical Care and Sleep Medicine, VMMC and Safdarjung Hospital, Delhi. Hauptthemen laut MEDLINE: Endoscopic Ultrasound-Guided Fine Needle Aspiration, Lymph Nodes, Bronchoscopy, Mediastinum. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endobronchial ultrasound (EBUS)-guided mediastinal cryobiopsy is a new modality for sampling mediastinal lymph nodes. The data regarding the diagnostic yield and utility of mediastinal cryobiopsy is still limited. Consecutive patients who were undergoing EBUS-guided transbronchial needle aspiration (EBUS-TBNA) were recruited in this study. We subjected the enrolled patients to EBUS-guided mediastinal cryobiopsy after obtaining their informed consent. The final diagnosis was made with a clinical-pathological-radiological assessment and clinical-radiological follow-up. A total of 101 patients were enrolled in the study. Adequacy in sampling achieved in EBUS-TBNA was 92.07%, compared to 98.01% achieved in EBUS-TBNA with mediastinal cryobiopsy. Diagnostic yields achieved in EBUS-TBNA and EBUS-TBNA with mediastinal cryobiopsy were 67.32% and 86.13%, respectively (p=0.001). EBUS patterns failed to predict the utility of mediastinal cryobiopsy. No significant complications were observed. To conclude, EBUS-guided mediastinal cryobiopsy improves yield in patients undergoing EBUS-TBNA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endoscopic Ultrasound-Guided Fine Needle AspirationLymph NodesBronchoscopyMediastinumMediastinal NeoplasmsLung NeoplasmsHumansMaleFemaleMiddle AgedIndiaTertiary Care CentersAgedAdultCryosurgery

Autor:innen und Institutionen

  • Department of Pulmonary, Critical Care and Sleep Medicine, VMMC and Safdarjung Hospital, Delhi.
  • SpR Transplant (lung) Medicine, Royal Brompton and Harefield Medicine, London.

ORCID-Profile: Yash Kedia

Zitieren

APA

Madan, M., Kumar, R., Ish, P., Kedia, Y., Mahendran, A. J., Kaushik, R., Gupta, N. K., & Gupta, N. (2024). Additional yield of transbronchial cryo‐node biopsy over endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal lesions at a tertiary care center in India (COLD-FORCEPS-2 study). Monaldi Archives for Chest Disease. https://doi.org/10.4081/monaldi.2024.3054

Vancouver

Madan M, Kumar R, Ish P, Kedia Y, Mahendran AJ, Kaushik R, et al. Additional yield of transbronchial cryo‐node biopsy over endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal lesions at a tertiary care center in India (COLD-FORCEPS-2 study). Monaldi Archives for Chest Disease. 2024. doi:10.4081/monaldi.2024.3054