Comparing Diagnostic Performance across Two High-Volume Endobronchial Ultrasound Services in Greater Manchester with and without Rapid On-Site Evaluation
Respiration · 2025
DOI: 10.1159/000545164 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Respiration, 2025. Verfasst von Haider Al-Najjar und 6 weiteren Autor:innen. Beteiligte Einrichtung: Manchester Royal Infirmary, Manchester University NHS Foundation Trust, Manchester, UK. Hauptthemen laut MEDLINE: Lung Neoplasms, Endoscopic Ultrasound-Guided Fine Needle Aspiration, Rapid On-site Evaluation, Lymph Nodes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Rapid On-Site Evaluation (ROSE) entails immediate pathological evaluation of diagnostic specimens in the procedure room, facilitating real-time feedback to operator on specimen adequacy and diagnosis. There is ongoing debate about its role in the field of endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration.
Methods
To re-evaluate the impact of ROSE, we completed a retrospective cohort analysis of prospectively maintained Greater Manchester EBUS database encompassing all linear EBUS procedures between 1 January 2017 and 31 December 2018 at the ROSE centre versus all linear EBUS procedures in the same period at a non-ROSE centre. Diagnostic performance plus procedural factors such as lymph node (LN) stations sampled and sedation doses were examined and then stratified according to EBUS indication.
Results
In total, 1,650 consecutive EBUS procedures were examined across two centres. Using ROSE resulted in statistically significant reduction in number of nodes sampled, time to pathology, and sedation doses for most indications. In 697 staging EBUS, sensitivity at the ROSE centre was 95% (95% CI 91–97%), negative predictive value (NPV) 93% (95% CI 88–96%) with prevalence of mediastinal nodal metastases of 27% (103/376) versus non-ROSE sensitivity 85% (95% CI 79–90%), NPV 86% (95% CI 80–90%) with prevalence of mediastinal nodal metastases of 32% (103/321). In 329 diagnostic EBUS, using ROSE resulted in a statistically significant reduction in number of LN stations sampled per procedure (median 1 station [1–1] with ROSE vs. 2 [1–2], p < 0.001). Diagnostic performance was higher at the ROSE centre including increases in sensitivity of 7% for diagnostic EBUS in advanced lung cancer, 20% for isolated mediastinal/hilar lymphadenopathy, and 17% for diagnosis of nodal metastases from extra-thoracic malignancy.
Conclusion
This study suggests ROSE may provide additional value in diagnostic performance in EBUS and warrants further discussion in an evolving lung cancer and bronchoscopic landscape.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Manchester Royal Infirmary, Manchester University NHS Foundation Trust, Manchester, UK.
- Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK.
Zitieren
APA
Al-Najjar, H., Almadhi, M., Rajai, A., Narine, N., Rana, D., Balata, H., & Evison, M. (2025). Comparing Diagnostic Performance across Two High-Volume Endobronchial Ultrasound Services in Greater Manchester with and without Rapid On-Site Evaluation. Respiration. https://doi.org/10.1159/000545164
Vancouver
Al-Najjar H, Almadhi M, Rajai A, Narine N, Rana D, Balata H, et al. Comparing Diagnostic Performance across Two High-Volume Endobronchial Ultrasound Services in Greater Manchester with and without Rapid On-Site Evaluation. Respiration. 2025. doi:10.1159/000545164
BibTeX
@article{AlNajjar2025,
author = {Al-Najjar, Haider and Almadhi, Marwah and Rajai, Azita and Narine, Nadira and Rana, Durgesh and Balata, Haval and Evison, Matthew},
title = {Comparing Diagnostic Performance across Two High-Volume Endobronchial Ultrasound Services in Greater Manchester with and without Rapid On-Site Evaluation},
journal = {Respiration},
year = {2025},
doi = {10.1159/000545164}
}