EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Early Complications of Epicardial Permanent Pacemaker Implantation in Neonates and Infants Weighing 5 kg or Less

Eung Soo Kim iD, Youngkwan Song iD, Dong-Hee Kim iD, Eun Seok Choi iD, Bo Sang Kwon iD, Chun Soo Park iD, Tae-Jin Yun iD

Korean Circulation Journal · 2027 · 57

DOI: 10.4070/kcj.2026.0321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Circulation Journal, 2027. Verfasst von Eung Soo Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: We evaluated the incidence and predictors of early complications following epicardial permanent pacemaker (ePPM) implantation in neonates and infants weighing 5 kg or less. METHODS: We retrospectively reviewed 40 patients weighing 5 kg or less who underwent ePPM implantation between 1999 and 2025. Early complications were defined as ePPM-related adverse events requiring medical or surgical intervention within 6 months post-implantation. Firth's penalized logistic regression was performed to identify predictors for early complications. Receiver operating characteristic (ROC) determined the optimal cutoff value. RESULTS: The median age and body weight at implantation were 58 days (interquartile range [IQR], 21.8-118.3 days) and 3.7 kg (IQR, 3.2-4.3 kg), respectively. Early complications occurred in 9 patients (22.5%), including wound dehiscence (n=5), pocket infection (n=3), and pericardial effusion (n=1). On multivariable analysis, body weight at implantation was an independent predictor of complications (odds ratio [OR], 0.77 per 100-g increase; 95% confidence interval [CI], 0.60-0.98; p=0.031). ROC analysis identified 3.5 kg as the optimal cutoff value for predicting early complications (area under the curve, 0.94; 95% CI, 0.87-1.00; p

Schlagwörter

Stichwörter der Autor:innen

ArrhythmiaPacemaker, ArtificialPostoperative complicationsinfantneonate

Autor:innen und Institutionen

  • Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Division of Pediatric Cardiac Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea. gninihs@amc.seoul.kr.

ORCID-Profile: Eung Soo Kim, Youngkwan Song, Dong-Hee Kim, Eun Seok Choi, Bo Sang Kwon, Chun Soo Park, Tae-Jin Yun

Zitieren

APA

Kim, E. S., Song, Y., Kim, D. H., Choi, E. S., Kwon, B. S., Park, C. S., & Yun, T. J. (2027). Early Complications of Epicardial Permanent Pacemaker Implantation in Neonates and Infants Weighing 5 kg or Less. Korean Circulation Journal, 57. https://doi.org/10.4070/kcj.2026.0321

Vancouver

Kim ES, Song Y, Kim DH, Choi ES, Kwon BS, Park CS, et al. Early Complications of Epicardial Permanent Pacemaker Implantation in Neonates and Infants Weighing 5 kg or Less. Korean Circulation Journal. 2027;57. doi:10.4070/kcj.2026.0321

BibTeX
@article{Kim2027,
  author = {Kim, Eung Soo and Song, Youngkwan and Kim, Dong-Hee and Choi, Eun Seok and Kwon, Bo Sang and Park, Chun Soo and Yun, Tae-Jin},
  title = {Early Complications of Epicardial Permanent Pacemaker Implantation in Neonates and Infants Weighing 5 kg or Less},
  journal = {Korean Circulation Journal},
  year = {2027},
  volume = {57},
  doi = {10.4070/kcj.2026.0321}
}
Kostenlos starten →