EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Computed Tomography Versus Simple Radiography for Detecting and Classifying Heterotopic Ossification after Reverse Shoulder Arthroplasty

Tae Kang Lim iD, Yun Sun Choi iD, Gu Min Jeong iD, Dong Kyun Kim iD, Myung-Sun Kim iD

Clinics in Orthopedic Surgery · 2024

DOI: 10.4055/cios24071 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinics in Orthopedic Surgery, 2024. Verfasst von Tae Kang Lim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Nowon Eulji Medical Center, Eulji University School of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Ossification, Heterotopic, Arthroplasty, Replacement, Shoulder, Tomography, X-Ray Computed. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Backgroud: Heterotopic ossification (HO) is difficult to characterize and classify on simple radiographs. Therefore, we attempted to evaluate intraobserver and interobserver reliability of simple radiography and computed tomography (CT) for detecting and classifying HO after reverse shoulder arthroplasty (RSA). It was hypothesized that CT would provide more reliable results than simple radiography.

Methods

This retrospective study reviewed 30 patients who underwent RSA performed by a single surgeon. Patients were included if they had both postoperative simple radiographs and CT images taken immediately after surgery and at 1 year after surgery and if they had completed clinical assessment at least 1 year after surgery. We first evaluated the intraobserver and interobserver reliability for the detection of the presence of HO and Modified Brooker's classification both on simple radiographs and CT scans with the use of Kappa statistics. Then, we analyzed the correlation of HO observed in simple radiographs and CT scans with clinical outcomes. All radiographic evaluations were performed by 2 independent reviewers in random orders with 3 weeks of intervals.

Results

The intraobserver reliability outcomes of both reviewers in simple radiography and CT were almost perfect or perfect for the detection of HO and classification. However, CT images improved the interobserver reliability for the detection of HO (kappa value for simple radiographs [KXR] = 0.6018 and kappa value for CT [KCT] = 0.8316) and classification (KXR = 0.5300 and KCT = 0.6964). At a mean follow-up of 25 months (range, 12-54 months), clinical scores were not significantly different according to the presence of HO based on simple radiographs. However, when CT images were used, the University of California, Los Angeles score and physical component score of short-form 36-item health survey were significantly lower in patients with HO than in patients without HO (27.0 vs. 30.4, p = 0.045 and 57.6 vs. 70.7, p = 0.034, respectively).

Conclusions

Both simple radiography and CT provided excellent intraobserver reliability for detecting and classifying HO after RSA. Compared to simple radiography, CT tended to improve interobserver reliability and defined the presence and severity of HO more clearly.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ossification, HeterotopicArthroplasty, Replacement, ShoulderTomography, X-Ray ComputedHumansRetrospective StudiesMaleFemaleAgedMiddle AgedReproducibility of ResultsObserver VariationAged, 80 and overPostoperative ComplicationsShoulder Joint

Stichwörter der Autor:innen

AcetubulumComplicationFractureOutcomePrognostic factor

Autor:innen und Institutionen

  • Department of Orthopedic Surgery, Nowon Eulji Medical Center, Eulji University School of Medicine, Seoul, Korea.
  • Department of Radiology, Nowon Eulji Medical Center, Eulji University School of Medicine, Seoul, Korea.
  • Department of Orthopedic Surgery, Chonnam National University Medical School and Hospital, Gwangju, Korea.

ORCID-Profile: Tae Kang Lim, Yun Sun Choi, Gu Min Jeong, Dong Kyun Kim, Myung-Sun Kim

Zitieren

APA

Lim, T. K., Choi, Y. S., Jeong, G. M., Kim, D. K., & Kim, M. S. (2024). Computed Tomography Versus Simple Radiography for Detecting and Classifying Heterotopic Ossification after Reverse Shoulder Arthroplasty. Clinics in Orthopedic Surgery. https://doi.org/10.4055/cios24071

Vancouver

Lim TK, Choi YS, Jeong GM, Kim DK, Kim MS. Computed Tomography Versus Simple Radiography for Detecting and Classifying Heterotopic Ossification after Reverse Shoulder Arthroplasty. Clinics in Orthopedic Surgery. 2024. doi:10.4055/cios24071

BibTeX
@article{Lim2024,
  author = {Lim, Tae Kang and Choi, Yun Sun and Jeong, Gu Min and Kim, Dong Kyun and Kim, Myung-Sun},
  title = {Computed Tomography Versus Simple Radiography for Detecting and Classifying Heterotopic Ossification after Reverse Shoulder Arthroplasty},
  journal = {Clinics in Orthopedic Surgery},
  year = {2024},
  doi = {10.4055/cios24071}
}
Kostenlos starten →