Comparison of the Usefulness of Computer-Assisted Three-Dimensional Analysis and Weight-Bearing Radiographs in Ankle Osteoarthritis
Clinics in Orthopedic Surgery · 2024
DOI: 10.4055/cios23221 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinics in Orthopedic Surgery, 2024. Verfasst von Si-Wook Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Daegu, Korea. Hauptthemen laut MEDLINE: Ankle, Osteoarthritis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Medical Device Development Fund.
Abstract (Originalsprache)
Background
To evaluate the degree of deformation in patients with ankle osteoarthritis (OA), it is essential to measure the three-dimensional (3D), in other words, stereoscopic alignment of the ankle, subtalar, and foot arches. Generally, measurement of radiological parameters use two-dimensional (2D) anteroposterior and lateral radiographs in a weight-bearing state; however, computer-aided 3D analysis (Disior) using weight-bearing cone-beam computed tomography (CBCT) has recently been introduced.
Methods
In this study, we compared the 2D human radiographic method with a stereoscopic image in patients with ankle arthritis. We enrolled 57 patients diagnosed with OA (28 left and 29 right) and obtained both standing radiographs and weight-bearing CBCT. Patients were divided by the Takakura stage. The interclass correlation coefficient (ICC) for each result was confirmed.
Results
On the ICC between 2D radiographs and 3D analysis, the tibiotalar surface angle and lateral talo-1st metatarsal angle showed a good ICC grade (> 0.6), while other parameters did not have significant ICC results. Three-dimension was superior to radiographs in terms of statistical significance.
Conclusions
We demonstrated that 2D and stereoscopic images are useful for the diagnosis of OA. Our study also confirmed that the radiographic features affected by ankle OA varied. However, according to the results, the typical radiography is not sufficient to diagnose and determine a treatment plan for ankle OA. Therefore, the method of using 3D images should be considered.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Daegu, Korea.
- Industry-Academic Cooperation Foundation, Keimyung University, Daegu, Korea.
- Department of Anatomy, Keimyung University College of Medicine, Daegu, Korea.
ORCID-Profile: Si-Wook Lee, Chang-Jin Yon, Jae-Ho Kim, Jung-Min Lee, Jae-Ho Lee, Yu-Ran Heo
Förderung
- Korea Medical Device Development Fund
Zitieren
APA
Lee, S. W., Yon, C. J., Kim, J. H., Lee, J. M., Lee, J. H., & Heo, Y. R. (2024). Comparison of the Usefulness of Computer-Assisted Three-Dimensional Analysis and Weight-Bearing Radiographs in Ankle Osteoarthritis. Clinics in Orthopedic Surgery. https://doi.org/10.4055/cios23221
Vancouver
Lee SW, Yon CJ, Kim JH, Lee JM, Lee JH, Heo YR. Comparison of the Usefulness of Computer-Assisted Three-Dimensional Analysis and Weight-Bearing Radiographs in Ankle Osteoarthritis. Clinics in Orthopedic Surgery. 2024. doi:10.4055/cios23221
BibTeX
@article{Lee2024,
author = {Lee, Si-Wook and Yon, Chang-Jin and Kim, Jae-Ho and Lee, Jung-Min and Lee, Jae-Ho and Heo, Yu-Ran},
title = {Comparison of the Usefulness of Computer-Assisted Three-Dimensional Analysis and Weight-Bearing Radiographs in Ankle Osteoarthritis},
journal = {Clinics in Orthopedic Surgery},
year = {2024},
doi = {10.4055/cios23221}
}
EUVIMED