Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements
Foot & Ankle International · 2023
DOI: 10.1177/10711007231173672 ↗Kurz gefasst
Kommentar in der Zeitschrift Foot & Ankle International, 2023. Verfasst von Ben Efrima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Ankle and Foot Unit, Humanitas San Pio X Hospital, Milan, Italy. Hauptthemen laut MEDLINE: Ankle, Arthroplasty, Replacement, Ankle. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
The current reference standard for postoperative evaluation of total ankle arthroplasty (TAA) positioning, weightbearing radiography (WBXR), is subject to technical bias. Weightbearing cone beam computed tomography (WBCT) enables visualization of the foot’s complex 3-dimensional (3D) structure under standing load. To date, no WBCT-based system for TAA positioning has been validated. The purpose of this study was to (1) assess TAA positioning using WBCT 3D models and (2) evaluate the agreement levels between 2 raters and thus evaluate the intermethod reliability with respect to WBXR.
Methods
Fifty-five consecutive patients were retrospectively reviewed. Two raters independently created a 3D WBCT model using dedicated software and recorded the following measurements: α angle, tibiotalar surface angle (TSA), hindfoot angle (HFA), tibiotalar ratio (TTR), β angle, γ angle, and Φ angle. Measurements were repeated 2 months apart in similar, independent fashion and compared to WBXR. Interobserver, intraobserver, and intermethod agreements were calculated.
Results
All 7 measurements showed good to excellent intraobserver and interobserver reliability (ICC 0.85-0.95). The intermethod (WBCT vs WBXR) agreement showed good agreement for the γ angle (ICC 0.79); moderate agreement levels for the α angle, TSA angle, β angle, and TTR (ICC 0.68, 0.69, 0.70, and 0.69, respectively); poor agreement for the HFA (ICC 0.25); and negative agreement for the φ angle (ICC −0.2).
Conclusion
Position analysis of TAA using WBCT demonstrated good to excellent interobserver and intraobserver agreement and can be reliably used. Additionally, a negative to moderate agreement between standard WBCT and standard WBXR was found. Level of Evidence: Level III, retrospective study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ankle and Foot Unit, Humanitas San Pio X Hospital, Milan, Italy.
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
ORCID-Profile: Ben Efrima, Agustin Barbero, Joshua E Ovadia, Cristian Indino, Federico Giuseppe Usuelli
Zitieren
APA
Efrima, B., Barbero, A., Ovadia, J. E., Indino, C., Maccario, C., & Usuelli, F. G. (2023). Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements. Foot & Ankle International. https://doi.org/10.1177/10711007231173672
Vancouver
Efrima B, Barbero A, Ovadia JE, Indino C, Maccario C, Usuelli FG. Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements. Foot & Ankle International. 2023. doi:10.1177/10711007231173672
BibTeX
@article{Efrima2023,
author = {Efrima, Ben and Barbero, Agustin and Ovadia, Joshua E and Indino, Cristian and Maccario, Camilla and Usuelli, Federico Giuseppe},
title = {Reliability of Cone Beam Weightbearing Computed Tomography Analysis of Total Ankle Arthroplasty Positioning and Comparison to Weightbearing X-Ray Measurements},
journal = {Foot & Ankle International},
year = {2023},
doi = {10.1177/10711007231173672}
}
EUVIMED