EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Influence of template design on the accuracy of static computer-assisted implant surgery

Jinmook Chung iD, Junghyun Park iD, Hyeonseong Son iD, Seoung-Jin Hong iD, Ahran Pae iD

The Journal of Advanced Prosthodontics · 2025 · 17 (1) · 22

DOI: 10.4047/jap.2025.17.1.22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Advanced Prosthodontics, 2025. Verfasst von Jinmook Chung und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Graduate School, Kyung Hee University, Seoul, Republic of Korea. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs. MATERIALS AND METHODS: Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1-4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5-6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models. RESULTS: While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation. CONCLUSION: Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.

Schlagwörter

Stichwörter der Autor:innen

Guided surgeryImplantOpen sleeveStatic computer-assisted implant surgery (s-CAIS)Surgical template

Autor:innen und Institutionen

  • Department of Dentistry, Graduate School, Kyung Hee University, Seoul, Republic of Korea.
  • Department of Prosthodontics, College of Dentistry, Kyung Hee University, Seoul, Republic of Korea.

ORCID-Profile: Jinmook Chung, Junghyun Park, Hyeonseong Son, Seoung-Jin Hong, Ahran Pae

Zitieren

APA

Chung, J., Park, J., Son, H., Hong, S. J., & Pae, A. (2025). Influence of template design on the accuracy of static computer-assisted implant surgery. The Journal of Advanced Prosthodontics, 17(1), 22. https://doi.org/10.4047/jap.2025.17.1.22

Vancouver

Chung J, Park J, Son H, Hong SJ, Pae A. Influence of template design on the accuracy of static computer-assisted implant surgery. The Journal of Advanced Prosthodontics. 2025;17(1):22. doi:10.4047/jap.2025.17.1.22

BibTeX
@article{Chung2025,
  author = {Chung, Jinmook and Park, Junghyun and Son, Hyeonseong and Hong, Seoung-Jin and Pae, Ahran},
  title = {Influence of template design on the accuracy of static computer-assisted implant surgery},
  journal = {The Journal of Advanced Prosthodontics},
  year = {2025},
  volume = {17},
  number = {1},
  pages = {22},
  doi = {10.4047/jap.2025.17.1.22}
}