EUVIMEDEUVIMED entdecken
Open Access

The accuracy of dental implant placement with different computer-assisted implant surgery techniques

Sindhu Sudhakar Kumararama, A B Nischitha, H Sneha, Bhavna Jha Kukreja, Md Jalaluddin, Ripal Parikh, Miral Mehta

Bioinformation · 31.03.2026 · 22 (3) · 1409-1415

DOI: 10.6026/973206300221409 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinformation, online erschienen am 31.03.2026. Verfasst von Sindhu Sudhakar Kumararama und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Crown & Bridge, Rajarajeswari Dental College and Hospital, Bengaluru, Karnataka, India. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite technological advances, achieving ideal three-dimensional precision in dental implant placement remains challenging, with deviations potentially affecting prosthetic outcomes and peri-implant health. Therefore, it is of interest to evaluate the accuracy of static computer-guided, dynamic computer-guided and conventional freehand implant placement techniques. Hence, a total of 120 implants were placed in 96 patients, with at least 40 implants per group and postoperative CBCT images were compared with preoperative plans to measure positional deviations. Both computer-guided approaches demonstrated significantly higher placement accuracy than the freehand method (p < 0.05). Dynamic navigation achieved the best accuracy with minimal coronal (0.71 ą 0.34 mm) and angular (2.18 ą 1.12°) deviations, indicating its slight advantage in clinical predictability over static guidance.

Schlagwörter

Stichwörter der Autor:innen

Dental implantscomputer-assisted surgerydynamic navigationimplant accuracystatic surgical guide

Autor:innen und Institutionen

  • Department of Prosthodontics, Crown & Bridge, Rajarajeswari Dental College and Hospital, Bengaluru, Karnataka, India.
  • Department Preventive Dental Sciences, Gulf Medical University, Ajman, UAE.
  • Department of Periodontics and Implantology, Kalinga Institute of Dental Sciences (KIDS), Campus-5, KIMS, KIIT Deemed University, Bhubaneswar-751024, Odisha, India.
  • Department of Periodontics, Dharmsinh Desai University, Gujarat, India.
  • Department of Pediatric and Preventive Dentistry, Karnavati School of Dentistry, Karnavati University, Gandhinagar, Gujarat, India.

Zitieren

APA

Kumararama, S. S., Nischitha, A. B., Sneha, H., Kukreja, B. J., Jalaluddin, M., Parikh, R., & Mehta, M. (2026). The accuracy of dental implant placement with different computer-assisted implant surgery techniques. Bioinformation, 22(3), 1409-1415. https://doi.org/10.6026/973206300221409

Vancouver

Kumararama SS, Nischitha AB, Sneha H, Kukreja BJ, Jalaluddin M, Parikh R, et al. The accuracy of dental implant placement with different computer-assisted implant surgery techniques. Bioinformation. 2026;22(3):1409-1415. doi:10.6026/973206300221409

BibTeX
@article{Kumararama2026,
  author = {Kumararama, Sindhu Sudhakar and Nischitha, A B and Sneha, H and Kukreja, Bhavna Jha and Jalaluddin, Md and Parikh, Ripal and Mehta, Miral},
  title = {The accuracy of dental implant placement with different computer-assisted implant surgery techniques},
  journal = {Bioinformation},
  year = {2026},
  volume = {22},
  number = {3},
  pages = {1409--1415},
  doi = {10.6026/973206300221409}
}
Kostenlos starten →