Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method
Korean Journal of Orthodontics · 25.11.2024 · 54 (6) · 359-373
DOI: 10.4041/kjod24.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Korean Journal of Orthodontics, online erschienen am 28.06.2024. Verfasst von Jong-Chan Baik und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Pusan National University Hospital.
Abstract (Originalsprache)
Objective
This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC).
Methods
The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/moment transducer when an extrusion of 0.5 mm was planned, assuming the mandibular first premolars were intruded by 1 mm. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-mm extended margins, equi-margins with 1-mm thickness and height, and equi-margins with 1-mm reduced buccolingual width. The CA was printed directly at a thickness of 0.5 mm, and the experiments were conducted at 37°C.
Results
The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency.
Conclusions
Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Korea.
- Department of Orthodontics, Biomedical Research Institute, Pusan National University Hospital, Busan, Korea.
- Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan, Korea.
- School of Computer Science and Engineering, Pusan National University, Busan, Korea.
- Department of Orthodontics, Saint Louis University, Saint Louis, MO, USA.
ORCID-Profile: Jong-Chan Baik, Youn-Kyung Choi, Yonghun Cho, Yunju Baek, Sung-Hun Kim, Seong-Sik Kim, Soo-Byung Park, Ki Beom Kim, Yong-Il Kim
Förderung
- Pusan National University Hospital
Zitieren
APA
Baik, J. C., Choi, Y. K., Cho, Y., Baek, Y., Kim, S. H., Kim, S. S., Park, S. B., Kim, K. B., & Kim, Y. I. (2024). Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method. Korean Journal of Orthodontics, 54(6), 359-373. https://doi.org/10.4041/kjod24.016
Vancouver
Baik JC, Choi YK, Cho Y, Baek Y, Kim SH, Kim SS, et al. Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method. Korean Journal of Orthodontics. 2024;54(6):359-373. doi:10.4041/kjod24.016
BibTeX
@article{Baik2024,
author = {Baik, Jong-Chan and Choi, Youn-Kyung and Cho, Yonghun and Baek, Yunju and Kim, Sung-Hun and Kim, Seong-Sik and Park, Soo-Byung and Kim, Ki Beom and Kim, Yong-Il},
title = {Evaluation of different designs of 3D printed clear aligners on mandibular premolar extrusion using force/moment measurement devices and digital image correlation method},
journal = {Korean Journal of Orthodontics},
year = {2024},
volume = {54},
number = {6},
pages = {359--373},
doi = {10.4041/kjod24.016}
}
EUVIMED