EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Comparison Between the Expansion Force Exerted by Thermo-Printed Aligners and 3D Printed Aligners: An In Vitro Study

Samuele Avolese iD, Simone Parrini iD, Andrea Tancredi Lugas iD, Cristina Bignardi iD, Mara Terzini iD, Valentina Cantù, Tommaso Castroflorio iD, Emanuele Grifalconi, Nicola Scotti iD, Fabrizio Sanna iD

Bioengineering · 25.08.2025 · 12 (9) · 912

DOI: 10.3390/bioengineering12090912 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 25.08.2025. Verfasst von Samuele Avolese und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10100 Torino, Italy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The fabrication of orthodontic aligners directly via three-dimensional (3D) printing presents potential to increase the efficiency of aligner production relative to traditional workflows; however, several aspects of the 3D printing process might affect the dimensional fidelity of the fabricated appliances. The aim of this study is to measure the forces expressed by a 3D printed aligner made with TC-85 DAC resin (Grapy Inc., Seoul, Republic of Korea) when an expansion movement of the entire upper dental arch is programmed, comparing the measured forces with those obtained by a common thermoformed aligner (Smart Track®, Align Technology, Santa Clara, CA, USA). Materials and methods: A patient in transitional mixed dentition was selected, with the presence of all the first molars and permanent upper and lower incisors, and the canines and premolars have not started the exchange. From this patient, a virtual set up of the upper arch has been planned with an expansion of 0.2 mm and 0.4 mm per side; 3 mm horizontal rectangular attachments were added to the set up on the vestibular surface of the permanent molars, deciduous premolars, and deciduous canines. On this set up, 10 Smart Track aligners and 10 3D printed aligners with TC-85 DAC resin were produced. The fabricated aligners were mounted on the machinery used for the test (ElectroForce® Test Bench; TA Instruments, New Castle, DE, USA) by means of specific supports that simulate the upper arch of the patient (divided into two sides: right and left). To simulate the intraoral environment, the measurements were carried out in a thermostatic bath at a temperature of 37 °C.

Results

The key results of this paper showed differences between Smart Track® and TC-85 DAC. In particular, the expanding force exerted by the 0.2 mm per side expanded Smart Track® aligners was on average +0.2162 N with a D.S. of ±0.0051 N during the 8 h; meanwhile, the force exerted by the 0.2 mm per side expanded TC-85 DAC 3D printed aligners was on average −0.0034 N with a D.S. of ±0.0036 N during the 8 h. The force exerted by the 0.4 mm per side expanded Smart Track® aligners was on average +0.7159 N with a D.S. of ±0.0543 N during the 8 h; meanwhile, the force exerted by the 0.4 mm per side expanded TC-85 DAC 3D printed aligners was on average +0.0141 N with a D.S. of ±0.004 N during the 8 h.

Conclusions

Smart Track® aligners express a quantitatively measurable force in Newtons during the programmed movements to obtain a posterior expansion of the dental arches; on the contrary, aligners made with TC-85 DAC resin, in light of the results obtained from this study, express forces close to 0 during the realization of the movements programmed to obtain a posterior expansion of the dental arches.

Schlagwörter

Stichwörter der Autor:innen

3D printed alignersaligner biomechanicsdigital orthodonticsforce measurementmixed dentitionorthodontic expansion

Autor:innen und Institutionen

  • Department of Mechanical and Aerospace Engineering, Polytechnic University of Turin, 10100 Torino, Italy.
  • Specialization School in Orthodontics, Department of Surgical Sciences, Dental School of the University of Torino, 10100 Torino, Italy.
  • PolitoBIOMed Lab, Polytechnic University of Turin, 10100 Torino, Italy.
  • Independent Researcher, 10100 Torino, Italy.
  • Department of Surgical Sciences, Dental School of the University of Torino, 10100 Torino, Italy.

ORCID-Profile: Samuele Avolese, Simone Parrini, Andrea Tancredi Lugas, Cristina Bignardi, Mara Terzini, Tommaso Castroflorio, Nicola Scotti, Fabrizio Sanna

Zitieren

APA

Avolese, S., Parrini, S., Lugas, A. T., Bignardi, C., Terzini, M., Cantù, V., Castroflorio, T., Grifalconi, E., Scotti, N., & Sanna, F. (2025). A Comparison Between the Expansion Force Exerted by Thermo-Printed Aligners and 3D Printed Aligners: An In Vitro Study. Bioengineering, 12(9), 912. https://doi.org/10.3390/bioengineering12090912

Vancouver

Avolese S, Parrini S, Lugas AT, Bignardi C, Terzini M, Cantù V, et al. A Comparison Between the Expansion Force Exerted by Thermo-Printed Aligners and 3D Printed Aligners: An In Vitro Study. Bioengineering. 2025;12(9):912. doi:10.3390/bioengineering12090912

BibTeX
@article{Avolese2025,
  author = {Avolese, Samuele and Parrini, Simone and Lugas, Andrea Tancredi and Bignardi, Cristina and Terzini, Mara and Cantù, Valentina and Castroflorio, Tommaso and Grifalconi, Emanuele and Scotti, Nicola and Sanna, Fabrizio},
  title = {A Comparison Between the Expansion Force Exerted by Thermo-Printed Aligners and 3D Printed Aligners: An In Vitro Study},
  journal = {Bioengineering},
  year = {2025},
  volume = {12},
  number = {9},
  pages = {912},
  doi = {10.3390/bioengineering12090912}
}
Kostenlos starten →