Fachartikel in der Zeitschrift Critical Care Nurse, 2023. Verfasst von Teresa Wood und 5 weiteren Autor:innen. Beteiligte Einrichtung: Teresa Wood is a nurse practitioner at Duke University Hospital, Durham, North Carolina. Hauptthemen laut MEDLINE: Enteral Nutrition, Intubation, Gastrointestinal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Background
Cardiothoracic surgery patients have an increased risk for aspiration and may require enteral access for nutrition. Local Problem In a cardiothoracic intensive care unit, feeding start times were delayed because of scheduling conflicts with support services. An electromagnetic device (Cortrak 2 Enteral Access System, Avanos Medical) was introduced to allow advanced practice providers (nurse practitioners and physician assistants) to independently establish postpyloric access and reduce dependence on ancillary services.
Methods
A quality improvement study was performed. Pre- and postimplementation data included order time, service arrival, tube placement time, tube positioning, and feeding start times for 207 placements. Pre- and postimplementation surveys were conducted to evaluate advanced practice provider satisfaction with enteral tube placement practices.
Results
Feeding start time for initial placement decreased by 35.5% (15.6 hours to 10 hours); for subsequent placement, by 55.2% (15.5 hours to 7.0 hours). Assistance by support services decreased by 80.4% (before implementation, 100 of 100 placements [100%]; after implementation, 21 of 107 placements [19.6%]; P < .001; ϕ = 0.815). Overall, advanced practice provider satisfaction increased. Most participants said that using the electromagnetic device was faster, nutrition was delivered sooner, and implementation was a valuable practice change.
Conclusions
Using an electromagnetic device decreased feeding start times, reduced the need for support services, and increased advanced practice provider satisfaction with small-bowel feeding tube placement practices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Teresa Wood is a nurse practitioner at Duke University Hospital, Durham, North Carolina.
- Valerie Sabol is a clinical professor and Interim Vice Dean at Duke University School of Nursing, Durham, North Carolina.
- Jill Engel is the Service Line Vice President for Heart & Vascular at Duke University Health System, Durham, North Carolina.
- Deborah H. Allen is a clinical nurse scientist and Director of Nursing Research and EBP at Duke University Health System.
- Julie A. Thompson is a consulting associate at Duke University School of Nursing.
- Tracey L. Yap is an associate professor at Duke University School of Nursing.
Zitieren
APA
Wood, T., Sabol, V., Engel, J., Allen, D. H., Thompson, J. A., & Yap, T. L. (2023). Using an Electromagnetic Guidance System for Placement of Small-Bowel Feeding Tubes to Reduce Feeding Start Times. Critical Care Nurse. https://doi.org/10.4037/ccn2023847
Vancouver
Wood T, Sabol V, Engel J, Allen DH, Thompson JA, Yap TL. Using an Electromagnetic Guidance System for Placement of Small-Bowel Feeding Tubes to Reduce Feeding Start Times. Critical Care Nurse. 2023. doi:10.4037/ccn2023847
BibTeX
@article{Wood2023,
author = {Wood, Teresa and Sabol, Valerie and Engel, Jill and Allen, Deborah H and Thompson, Julie A and Yap, Tracey L},
title = {Using an Electromagnetic Guidance System for Placement of Small-Bowel Feeding Tubes to Reduce Feeding Start Times},
journal = {Critical Care Nurse},
year = {2023},
doi = {10.4037/ccn2023847}
}
EUVIMED