Small‐bore feeding tubes placed with an electromagnetic imaging device leads to cost avoidance and decreased time to initiation of enteral nutrition

Michaelann Hahn, Laura Byham-Gray, Hamed Samavat, Susan Roberts, Rebecca Brody

Nutrition in Clinical Practice · 2023

DOI: 10.1002/ncp.10979 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nutrition in Clinical Practice, 2023. Verfasst von Michaelann Hahn und 4 weiteren Autor:innen. Beteiligte Einrichtung: Baylor Simmons Transplant Institute, Baylor University Medical Center, Dallas, Texas, USA. Hauptthemen laut MEDLINE: Enteral Nutrition, Intubation, Gastrointestinal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Cortrak Enteral Access System (CEAS) was previously approved by the United States Food and Drug Administration (FDA) to be used in lieu of radiographic confirmation imaging for feeding tubes placed by trained clinicians. Following an institutional protocol change in 2016, our registered dietitians had the option to forgo radiographic confirmation imaging for tubes placed using the CEAS. Our research aimed to determine the difference in the number of radiographic confirmation images for feeding tubes placed using the CEAS between preprotocol and postprotocol environments and the associated cost avoidance after the institutional policy change.

Methods

We retrospectively reviewed data from 506 tube placements ( n = 253 per protocol environment) in adult patients with diverse diagnoses admitted to various in‐patient care units.

Results

There was a significant reduction in the mean number of radiographic images per tube placement (preprotocol = 1.10 [95% CI, 1.05–1.15]; postprotocol = 0.36 [95% CI, 0.30–0.41]; P < 0.001), leading to a cost avoidance of $67,282.80 for the 253 tube placements and a potential cost avoidance of $279,236 over the 5‐year postprotocol environment. Additionally, the mean time to initiation of enteral nutrition was significantly reduced by 2.65 h in the postprotocol environment ( P < 0.001).

Conclusion

Our findings suggest that using the CEAS can reduce the number of radiographic images, provide cost avoidance, and improve nutrition outcomes. However, updated 2022 FDA regulatory changes to the use of the CEAS for tube confirmation lead to an uncertain future for this practice because of safety concerns.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Enteral NutritionIntubation, GastrointestinalAdultHumansRetrospective StudiesElectromagnetic PhenomenaIntestine, Small

Stichwörter der Autor:innen

enteral nutritionfeeding tube placementnutrition supportoutcomespatient safetyx-rays

Autor:innen und Institutionen

  • Baylor Simmons Transplant Institute, Baylor University Medical Center, Dallas, Texas, USA.
  • Departement of Clinical and Preventive Nutrition Sciences, Rutgers School of Health Professions, Rutgers University, Newark, New Jersey, USA.
  • Nutrition and Dietetics Education Program, Keiser University, Florida, USA.

Zitieren

APA

Hahn, M., Byham-Gray, L., Samavat, H., Roberts, S., & Brody, R. (2023). Small‐bore feeding tubes placed with an electromagnetic imaging device leads to cost avoidance and decreased time to initiation of enteral nutrition. Nutrition in Clinical Practice. https://doi.org/10.1002/ncp.10979

Vancouver

Hahn M, Byham-Gray L, Samavat H, Roberts S, Brody R. Small‐bore feeding tubes placed with an electromagnetic imaging device leads to cost avoidance and decreased time to initiation of enteral nutrition. Nutrition in Clinical Practice. 2023. doi:10.1002/ncp.10979

BibTeX
@article{Hahn2023,
  author = {Hahn, Michaelann and Byham-Gray, Laura and Samavat, Hamed and Roberts, Susan and Brody, Rebecca},
  title = {Small‐bore feeding tubes placed with an electromagnetic imaging device leads to cost avoidance and decreased time to initiation of enteral nutrition},
  journal = {Nutrition in Clinical Practice},
  year = {2023},
  doi = {10.1002/ncp.10979}
}
Kostenlos starten →