Clinically validated deep learning auto-contouring for glioblastoma volumetric modulated arc therapy planning: a dosimetric equivalence study
Radiation Oncology Journal · 31.03.2026 · 44 (1) · 53-68
DOI: 10.3857/roj.2025.00808 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Oncology Journal, erschienen am 31.03.2026. Verfasst von Omar Hamzaoui und 5 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Theoretical Physics, Particles, Modeling, and Energies, Faculty of Sciences, Mohammed First University, Oujda, Morocco. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0).
Abstract (Originalsprache)
Purpose
Manual delineation of target volumes and organs-at-risk (OARs) for glioblastoma radiotherapy is a critical bottleneck prone to inter-observer variability. This study developed a fully automated, dual-modality deep learning framework to validate its clinical utility by demonstrating the dosimetric equivalence of generated contours against an expert standard.Materials and Methods: A deep learning framework was developed using a retrospective dataset of 100 patients. It integrates two specialized networks operating without pre-alignment: a specialized dual-encoder attention U-Net for computed tomography (CT) (used for OARs delineation and dose calculation), and a single-encoder attention U-Net for T2-FLAIR magnetic resonance imaging (MRI) (used for precise target volumes definition). A modality dispatcher routes images to the appropriate model. Geometric performance was evaluated using the Dice similarity coefficient (DSC). For clinical validation, automated CT contours were used to generate volumetric modulated arc therapy plans. These plans were compared to those based on expert manual contours via paired statistical analysis.
Results
The framework demonstrated excellent geometric accuracy on the independent test set. Mean planning target volume (PTV) DSC was 0.94 ± 0.03 on MRI and 0.92 ± 0.04 on CT. Dosimetric analysis confirmed clinical viability. No statistically significant differences (p > 0.05) were observed between automated and manual plans for PTV coverage (D₉₅%), OAR maximum doses, or any evaluated metric.
Conclusion
The automated framework provides accurate segmentation on both CT and MRI. Demonstrated dosimetric equivalence validates clinical reliability and potential to enhance planning efficiency while reducing inter-observer variability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of Theoretical Physics, Particles, Modeling, and Energies, Faculty of Sciences, Mohammed First University, Oujda, Morocco.
- National Institute for Research in Particle Physics and its Applications, Oujda, Morocco.
- National School of Applied Sciences, Mohammed First University, Oujda, Morocco.
Zitieren
APA
Hamzaoui, O., Oulhouq, Y., Rezzoug, M., Zerfaoui, M., Bakkari, D., & Rrhioua, A. (2026). Clinically validated deep learning auto-contouring for glioblastoma volumetric modulated arc therapy planning: a dosimetric equivalence study. Radiation Oncology Journal, 44(1), 53-68. https://doi.org/10.3857/roj.2025.00808
Vancouver
Hamzaoui O, Oulhouq Y, Rezzoug M, Zerfaoui M, Bakkari D, Rrhioua A. Clinically validated deep learning auto-contouring for glioblastoma volumetric modulated arc therapy planning: a dosimetric equivalence study. Radiation Oncology Journal. 2026;44(1):53-68. doi:10.3857/roj.2025.00808
BibTeX
@article{Hamzaoui2026,
author = {Hamzaoui, Omar and Oulhouq, Yassine and Rezzoug, Mohammed and Zerfaoui, Mustapha and Bakkari, Dikra and Rrhioua, Abdeslem},
title = {Clinically validated deep learning auto-contouring for glioblastoma volumetric modulated arc therapy planning: a dosimetric equivalence study},
journal = {Radiation Oncology Journal},
year = {2026},
volume = {44},
number = {1},
pages = {53--68},
doi = {10.3857/roj.2025.00808}
}
EUVIMED