Abstract (original language)

Flexible ureteroscopy (fURS) is a mainstay of treatment for intrarenal stones, and the position of the working channel determines the direction from which a basket or other instrument enters the endoscopic field. Working channel position (WCP) has nevertheless received little systematic evaluation as a design variable, and ureteroscopes with a 6 o'clock channel have not previously been compared with conventional 3 and 9 o'clock designs. It was hypothesized that ureteroscopes with different working channel configurations would show measurable, task-specific differences in navigation, stone interaction, and operator ergonomics under standardized conditions. Four digital ureteroscopes representing 3 o'clock (Flex-Xc, LithoVue), 6 o'clock (URUS), and 9 o'clock (Lscope) configurations were evaluated in a life-size three-dimensional printed model of the right and left collecting systems reconstructed from a de-identified patient computed tomography dataset. A single experienced endourologist performed timed navigation to each color-coded calyx, quantification of calyceal visualization using predefined intracalyceal surface dots, ureteroscope-tip contact with artificial stones, basket relocation of a stone from the lower-posterior to the upper-posterior calyx, and assessment of wrist range of motion and self-reported fatigue. Differences in navigation time, calyceal visualization, relocation time, wrist range of motion, and operator-reported comfort were observed among ureteroscopes with different working channel configurations, and these differences varied by kidney side and calyx location. Flex-Xc showed the shortest navigation times in selected calyces, URUS showed more consistent stone relocation between the two kidneys together with favorable operator-reported comfort, and Lscope required longer completion times in the right kidney. Because the devices also differed in diameter, deflection, weight, and single-use versus reusable design, these differences cannot be attributed to WCP alone. The findings identify working channel configuration as a potentially relevant design factor that requires controlled and clinical validation.

Subjects

MeSH terms (MEDLINE)

UreteroscopesUreteroscopyHumansEquipment DesignKidney Calculi

Authors and institutions

  • Urology Medical Staff Group, Universitas Indonesia Hospital, Universitas Indonesia.
  • Department of Urology, Hue Central Hospital.
  • Department of Urology, Jose R. Reyes Memorial Medical Center.
  • Division of Urology, S.H. Ho Urology Centre, Department of Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong.
  • Department of Urology, King Fahd General Hospital.
  • Division of Urology, Department of Surgery, University of the Philippines - Philippine General Hospital.

Cite

APA

Parikesit, D., Nguyen Van, Q. A., Castillo, C. J., Yuen, S. K. K., Alharthi, M., Elises, J. C. R., & Cho, S. Y. (2026). Working Channel Position and Flexible Ureteroscope Performance: An In Vitro Comparative Study. Journal of Visualized Experiments. https://doi.org/10.3791/73167

Vancouver

Parikesit D, Nguyen Van QA, Castillo CJ, Yuen SKK, Alharthi M, Elises JCR, et al. Working Channel Position and Flexible Ureteroscope Performance: An In Vitro Comparative Study. Journal of Visualized Experiments. 2026. doi:10.3791/73167

BibTeX
@article{Parikesit2026,
  author = {Parikesit, Dyandra and Nguyen Van, Quoc Anh and Castillo, Christine Joy and Yuen, Steffi Kar Kei and Alharthi, Majed and Elises, Jose Carlo R and Cho, Sung Yong},
  title = {Working Channel Position and Flexible Ureteroscope Performance: An In Vitro Comparative Study},
  journal = {Journal of Visualized Experiments},
  year = {2026},
  number = {237},
  doi = {10.3791/73167}
}
Start for free →