EUVIMEDEUVIMED entdecken
Video/Audio

Safety Assessment of High Integrity Containers for Radioactive Waste in the Environment of a Chinese Disposal Site

Ke Wang, Jinghui Zhang, Tingsong Cai, Tiejun Liu, Baihua Jiang

Journal of Visualized Experiments · 03.11.2026 · (237)

DOI: 10.3791/72413 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Journal of Visualized Experiments, online erschienen am 03.11.2026. Verfasst von Ke Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: China Nuclear Power Engineering Co., Ltd. Hauptthemen laut MEDLINE: Radioactive Waste, Construction Materials, Waste Disposal Facilities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As global production of low- and intermediate-level radioactive waste continues to increase, safe containment and long-term disposal remain major challenges for the nuclear industry. High-integrity containers (HICs) serve as critical engineered barriers in near-surface disposal facilities by limiting radionuclide release and isolating radioactive waste from the biosphere. This study systematically assesses the long-term durability and containment performance of concrete HIC waste packages under the environmental conditions of a radioactive waste disposal site in China. The dominant degradation mechanisms were identified, and the environmental factors and material parameters governing each process were evaluated. Durability-degradation models were used to quantify the long-term effects of radionuclide migration, Ca2+ leaching, SO42- attack, carbonation, and Cl- attack. Under a pore moisture content of 0.7, an internal radionuclide concentration of 1 × 10-5 mol/L, a porosity of ≤12%, and a 137Cs diffusion coefficient of ≤0.1 mm2/day, the maximum released activity over 300 years was 9.19 × 10-6 Bq, well below the exemption limit of 104 Bq specified in GB 18871-2002. After 300 years, Ca2+ leaching reached approximately 4% of the 100 mm wall thickness. The calculated SO42- attack depth was 0.05 mm under site conditions and 1.70 mm under an extreme SO42- concentration of 10,000 mg/L. Carbonation and Cl- attack produced limited effects under the modeled conditions. These results indicate that concrete HIC waste packages can maintain structural integrity and containment performance throughout the 300-year disposal period at the investigated site under the modeled conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radioactive WasteConstruction MaterialsWaste Disposal FacilitiesChina

Substanzen

Radioactive Waste

Autor:innen und Institutionen

  • China Nuclear Power Engineering Co., Ltd.
  • China Nuclear Power Engineering Co., Ltd.; wktracy@163.com.

Zitieren

APA

Wang, K., Zhang, J., Cai, T., Liu, T., & Jiang, B. (2026). Safety Assessment of High Integrity Containers for Radioactive Waste in the Environment of a Chinese Disposal Site. Journal of Visualized Experiments. https://doi.org/10.3791/72413

Vancouver

Wang K, Zhang J, Cai T, Liu T, Jiang B. Safety Assessment of High Integrity Containers for Radioactive Waste in the Environment of a Chinese Disposal Site. Journal of Visualized Experiments. 2026. doi:10.3791/72413

BibTeX
@article{Wang2026,
  author = {Wang, Ke and Zhang, Jinghui and Cai, Tingsong and Liu, Tiejun and Jiang, Baihua},
  title = {Safety Assessment of High Integrity Containers for Radioactive Waste in the Environment of a Chinese Disposal Site},
  journal = {Journal of Visualized Experiments},
  year = {2026},
  number = {237},
  doi = {10.3791/72413}
}
Kostenlos starten →