EUVIMEDOpdag EUVIMED
Video/Audio

Improving MRI-Negative Epilepsy Localization: Synergy of Dual-Probe PET/MR (18F-FDG/11C-FMZ)

Yusong Pei, Zhiguo Wang, Xiaodan Wu, Jia Guo, Yingxin Dai, Guoxu Zhang, Jigang Wang

Journal of Visualized Experiments · 2025

DOI: 10.3791/69386 ↗

At a glance

Video/Audio in Journal of Visualized Experiments, 2025. Written by Yusong Pei and 6 co-authors. Institution: Department of Nuclear Medicine, General Hospital of Northern Theater Command. Major MEDLINE topics: Positron-Emission Tomography, Fluorodeoxyglucose F18, Magnetic Resonance Imaging, Epilepsy. Cited 1 times so far (Crossref); 41 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

The localization of refractory epilepsy, especially MRI-negative cases, is a critical challenge in diagnosing and treating neurological disorders. To address this challenge, this study proposes a standardized protocol for localizing the epileptogenic focus using a dual-probe Positron Emission Tomography/Magnetic Resonance Imaging (PET/MR) technique. The protocol focuses on radiotracer selection, imaging sequence design, and image interpretation strategies. Radiotracers selection: This imaging combines ¹⁸F-fluorodeoxyglucose (18F-FDG) metabolic imaging and 11C-flumazenil (11C-FMZ) GABA_A receptor imaging to locate epileptogenic focus in refractory epilepsy patients by detecting glucose metabolism abnormalities and GABA_A receptor density changes; imaging sequence design: FDG PET/MR scans were done first, followed by FMZ PET/MR scans 24 h later, MRI Sequence images including structural and functional images; image interpretation strategy: The dual-probe evaluation strategy identifies potential epileptogenic focus through FDG hypometabolism and FMZ binding reduction, with concurrent findings providing strong evidence, quantitative analysis involves standardized uptake values (SUV) and asymmetry index (AI) of FDG and FMZ images. This study details the preparation process of radiotracers, scanning parameters, and image fusion methods, validating the protocol's effectiveness through representative results. The adoption of dual-probe PET/MR imaging technology may enhance the accuracy of epileptogenic focus localization, thereby supporting more precise assessments and improving treatment outcomes. Currently, this protocol has completed methodological validation, and preliminary results indicate its potential to guide preoperative assessment for clinical epileptogenic focus resection (successful surgery was performed in 3 patients based on localization results, with no post-operative seizures). To address technical limitations (e.g., short 11C-FMZ half-life, cyclotron dependency), optimization directions include developing long-half-life analogues and exploring multi-tracer combinations. Future integration with AI-assisted image analysis and lesion identification is also feasible. In summary, this study offers novel insights for precision epilepsy diagnosis and treatment, holding significant implications for improving patient outcomes.

Subjects

MeSH terms (MEDLINE)

Positron-Emission TomographyFluorodeoxyglucose F18Magnetic Resonance ImagingEpilepsyFlumazenilMultimodal ImagingHumansRadiopharmaceuticalsCarbon RadioisotopesFemaleAdultMale

Substances

Fluorodeoxyglucose F18FlumazenilRadiopharmaceuticalsCarbon Radioisotopes

Authors and institutions

  • Department of Nuclear Medicine, General Hospital of Northern Theater Command.
  • Department of Nuclear Medicine, General Hospital of Northern Theater Command; zhangguoxu_502@163.com.
  • Department of Haematology, General Hospital of Northern Theater Command; ynjg_w@163.com.

Cite

APA

Pei, Y., Wang, Z., Wu, X., Guo, J., Dai, Y., Zhang, G., & Wang, J. (2025). Improving MRI-Negative Epilepsy Localization: Synergy of Dual-Probe PET/MR (18F-FDG/11C-FMZ). Journal of Visualized Experiments. https://doi.org/10.3791/69386

Vancouver

Pei Y, Wang Z, Wu X, Guo J, Dai Y, Zhang G, et al. Improving MRI-Negative Epilepsy Localization: Synergy of Dual-Probe PET/MR (18F-FDG/11C-FMZ). Journal of Visualized Experiments. 2025. doi:10.3791/69386

BibTeX
@article{Pei2025,
  author = {Pei, Yusong and Wang, Zhiguo and Wu, Xiaodan and Guo, Jia and Dai, Yingxin and Zhang, Guoxu and Wang, Jigang},
  title = {Improving MRI-Negative Epilepsy Localization: Synergy of Dual-Probe PET/MR (18F-FDG/11C-FMZ)},
  journal = {Journal of Visualized Experiments},
  year = {2025},
  doi = {10.3791/69386}
}
Start for free →