EUVIMEDEUVIMED entdecken
Video/Audio

Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF

Ajay Krishnan, Mahesh Sagar, Shivanand Mayi, Ravi Ranjan Rai, Mirant Dave, Mikeson Panthackel, Arjit Vashishtha, Amritesh Singh, Preety Krishnan, Mukesh Patel, Bharat Dave

Journal of Visualized Experiments · 2025

DOI: 10.3791/69192 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Journal of Visualized Experiments, 2025. Verfasst von Ajay Krishnan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Spine Surgery, Stavya Spine Hospital & Research Institute, Nr Nagari Hospital; drajaykrishnan@gmail.com. Hauptthemen laut MEDLINE: Minimally Invasive Surgical Procedures, Spinal Fusion, Imaging, Three-Dimensional, Lumbar Vertebrae. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) has become increasingly popular due to reduced tissue trauma, decreased blood loss, and faster recovery compared to traditional open procedures. The integration of 3D CT-based intraoperative navigation has significantly enhanced surgical precision and workflow optimization, potentially leading to better outcomes. However, workflow optimization has not been qualitatively or quantitatively assessed in MIS TLIF, and there may be an increase in setup and waiting times between surgeries in exchange for improved precision. In this retrospective study at a tertiary spine center, 44 patients undergoing fully navigated MIS TLIF were evaluated. A total of 176 pedicle screws were inserted using a sequential, navigation-guided workflow tailored to TLIF and decompression. Surgical accuracy, functional outcomes, perioperative safety, and workflow efficiency were assessed. The findings revealed significant improvements in Oswestry disability index (ODI) and numerical rating scale (NRS) scores, minimal blood loss, short operative times, and high screw placement precision (6.81% Grade 1 breaches). This article supports the clinical reliability and reproducibility of a fully navigated O-arm-assisted MIS TLIF protocol, offering qualitative evidence of improved workflow not previously reported.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Minimally Invasive Surgical ProceduresSpinal FusionImaging, Three-DimensionalLumbar VertebraeTomography, X-Ray ComputedSurgery, Computer-AssistedHumansWorkflowFemaleMiddle AgedRetrospective StudiesMaleAgedAdultPedicle Screws

Autor:innen und Institutionen

  • Department of Spine Surgery, Stavya Spine Hospital & Research Institute, Nr Nagari Hospital; drajaykrishnan@gmail.com.
  • Department of Spine Surgery, Stavya Spine Hospital & Research Institute, Nr Nagari Hospital.
  • Department of Spine Surgery, Stavya Spine Hospital & Research Institute, Nr Nagari Hospital; Department of Radiodiagnosis, Stavya Spine Hospital & Research Institute, Nr Nagari Hospital.

Zitieren

APA

Krishnan, A., Sagar, M., Mayi, S., Rai, R. R., Dave, M., Panthackel, M., Vashishtha, A., Singh, A., Krishnan, P., Patel, M., & Dave, B. (2025). Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF. Journal of Visualized Experiments. https://doi.org/10.3791/69192

Vancouver

Krishnan A, Sagar M, Mayi S, Rai RR, Dave M, Panthackel M, et al. Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF. Journal of Visualized Experiments. 2025. doi:10.3791/69192

BibTeX
@article{Krishnan2025,
  author = {Krishnan, Ajay and Sagar, Mahesh and Mayi, Shivanand and Rai, Ravi Ranjan and Dave, Mirant and Panthackel, Mikeson and Vashishtha, Arjit and Singh, Amritesh and Krishnan, Preety and Patel, Mukesh and Dave, Bharat},
  title = {Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF},
  journal = {Journal of Visualized Experiments},
  year = {2025},
  doi = {10.3791/69192}
}
Kostenlos starten →