Development of a Low-cost Epimysial Electromyography Electrode: A Simplified Workflow for Fabrication and Testing
Journal of Visualized Experiments · 2024
DOI: 10.3791/66744 ↗At a glance
Video/Audio in Journal of Visualized Experiments, 2024. Written by Luke Stoneback and 4 co-authors. Institution: School of Kinesiology, University of Michigan, Ann Arbor; lukeston@umich.edu. Major MEDLINE topics: Electromyography, Electrodes, Implanted. Cited 1 times so far (Crossref); 25 references. The full text is freely available in PubMed Central. Funded by: NIAMS NIH HHS.
Abstract (original language)
Electromyography (EMG) is a valuable diagnostic tool for detecting neuromuscular abnormalities. Implantable epimysial electrodes are commonly used to measure EMG signals in preclinical models. Although classical resources exist describing the principles of epimysial electrode fabrication, there is a sparsity of illustrative information translating electrode theory to practice. To remedy this, we provide an updated, easy-to-follow guide on fabricating and testing a low-cost epimysial electrode. Electrodes were made by folding and inserting two platinum-iridium foils into a precut silicone base to form the contact surfaces. Next, coated stainless steel wires were welded to each contact surface to form the electrode leads. Lastly, a silicone mixture was used to seal the electrode. Ex vivo testing was conducted to compare our custom-fabricated electrode to an industry standard electrode in a saline bath, where high levels of signal agreement (sine [intraclass correlation - ICC= 0.993], square [ICC = 0.995], triangle [ICC = 0.958]), and temporal-synchrony (sine [r = 0.987], square [r = 0.990], triangle [r= 0.931]) were found across all waveforms. Low levels of electrode impedance were also quantified via electrochemical impedance spectroscopy. An in vivo performance assessment was also conducted where the vastus lateralis muscle of a rat was surgically instrumented with the custom-fabricated electrode and signaling was acquired during uphill and downhill walking. As expected, peak EMG activity was significantly lower during downhill walking (0.008 ± 0.005 mV) than uphill (0.031 ± 0.180 mV, p = 0.005), supporting the validity of the device. The reliability and biocompatibility of the device were also supported by consistent signaling during level walking at 14 days and 56 days post implantation (0.01 ± 0.007 mV, 0.012 ± 0.007 mV respectively; p > 0.05) and the absence of histological inflammation. Collectively, we provide an updated workflow for the fabrication and testing of low-cost epimysial electrodes.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- School of Kinesiology, University of Michigan, Ann Arbor; lukeston@umich.edu.
- University of Michigan Medical School.
- School of Kinesiology, University of Michigan, Ann Arbor.
- School of Kinesiology, University of Michigan, Ann Arbor; llepley@umich.edu.
Funding
- NIAMS NIH HHS
Cite
APA
Stoneback, L., Fullano, G. D., White, M. S., Naaz, S., & Lepley, L. K. (2024). Development of a Low-cost Epimysial Electromyography Electrode: A Simplified Workflow for Fabrication and Testing. Journal of Visualized Experiments. https://doi.org/10.3791/66744
Vancouver
Stoneback L, Fullano GD, White MS, Naaz S, Lepley LK. Development of a Low-cost Epimysial Electromyography Electrode: A Simplified Workflow for Fabrication and Testing. Journal of Visualized Experiments. 2024. doi:10.3791/66744
BibTeX
@article{Stoneback2024,
author = {Stoneback, Luke and Fullano, Genaro D and White, McKenzie S and Naaz, Sairub and Lepley, Lindsey K},
title = {Development of a Low-cost Epimysial Electromyography Electrode: A Simplified Workflow for Fabrication and Testing},
journal = {Journal of Visualized Experiments},
year = {2024},
doi = {10.3791/66744}
}
EUVIMED