EUVIMEDOpdag EUVIMED
Video/Audio

A Modified Method for Intrathecal Catheterization in Rats

Lijun Yin, Quan Zhou, Wenwu Liu, Lize Xiong, Hui Chen

Journal of Visualized Experiments · 2025

DOI: 10.3791/66487 ↗

At a glance

Video/Audio in Journal of Visualized Experiments, 2025. Written by Lijun Yin and 4 co-authors. Institution: Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Tr…. Major MEDLINE topics: Catheterization, Injections, Spinal. Cited 1 times so far (Crossref); 16 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Intrathecal catheterization has been widely applied in animal experiments, especially those on neuropathic pain. However, the traditional methods still have several limitations. Although some investigators have attempted to improve the traditional methods, the available methods still need to be modified. Herein, we introduce a modified method for intrathecal catheterization in rats. This method uses a 20 cm long stainless-steel wire (0.2 mm in diameter), a 15 cm long plastic PE10 tube, a self-made sealing cap, and a 0.3 cm × 0.5 cm anti-allergic band. Our modified method for intrathecal catheterization has several advantages. First, introducing a stainless-steel wire to PE10 tube increases the elasticity of the tube, improves the success rate of intrathecal catheterization, reduces the amount of space required for the operation, and minimizes the damage to the tissues around the lumbar spine. Second, the length of PE10 tube is determined before the surgery, and catheter indwelling time can be longer than one week. Third, the PE10 tube is fixed by a figure-8 suture, 4 times, which prevents tube movement and retraction when the animal moves. Fourth, a self-made sealing cap is used to seal the PE10 tube, which not only prevents cerebrospinal fluid leakage but also reduces the need for repeated cutting of PE10 tube. Finally, the extracorporeal end of PE10 tube is tied with a band, which prevents tube retraction when the animal moves. This method can increase the catheterization success rate in rats, as approximately 80% of PE10 tubes remained in place even 28 days after surgery. Thus, this modified method may represent a simple, convenient, and reliable approach for repetitive intrathecal drug administration.

Subjects

MeSH terms (MEDLINE)

CatheterizationInjections, SpinalAnimalsRatsRats, Sprague-Dawley

Authors and institutions

  • Shanghai Key Laboratory of Anesthesiology and Brain Functional Modulation, Clinical Research Center for Anesthesiology and Perioperative Medicine, Translational Research Institute of Brain and Brain-Like Intelligence, D…
  • Department of Naval Diving Medicine, Naval Medical Center, Naval Medical University.
  • Department of Diving and Hyperbaric Medicine, Naval Medical Center, Naval Medical University.

Cite

APA

Yin, L., Zhou, Q., Liu, W., Xiong, L., & Chen, H. (2025). A Modified Method for Intrathecal Catheterization in Rats. Journal of Visualized Experiments. https://doi.org/10.3791/66487

Vancouver

Yin L, Zhou Q, Liu W, Xiong L, Chen H. A Modified Method for Intrathecal Catheterization in Rats. Journal of Visualized Experiments. 2025. doi:10.3791/66487

BibTeX
@article{Yin2025,
  author = {Yin, Lijun and Zhou, Quan and Liu, Wenwu and Xiong, Lize and Chen, Hui},
  title = {A Modified Method for Intrathecal Catheterization in Rats},
  journal = {Journal of Visualized Experiments},
  year = {2025},
  doi = {10.3791/66487}
}
Start for free →