EUVIMEDOpdag EUVIMED
Crossref

Development and Validation of a Photonumeric Scale for Evaluation of Infraorbital Hollowing

Brian Biesman, Amit Verma, Nuo Cheng, Ashlee Duncan

Journal of Drugs in Dermatology · 2023

DOI: 10.36849/jdd.7191 ↗

At a glance

Journal article in Journal of Drugs in Dermatology, 2023. Written by Brian Biesman and 3 co-authors. Major MEDLINE topics: Photography. Cited 3 times so far (Crossref).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

BACKGROUND: The infraorbital hollow is characterized by a sunken hollowing appearance of the junction between the lower eyelid and the cheek. Dermal fillers provide a suitable option to reduce the appearance of infraorbital hollowing. To objectively evaluate treatmentrelated improvements in clinical practice and research, a validated photonumeric scale is needed. OBJECTIVE: To present the scale development methods for the Merz Infraorbital Hollow Assessment Scale and establish its reliability and clinical relevance. METHODS: A 5-point photonumeric scale was developed to objectively assess the infraorbital hollowing among subjects of varying sex, age, and skin type. Intra- and inter-rater reliability was evaluated using live assessments conducted 2 weeks apart. The clinical relevance of a 1-point difference in scale-severity grade was evaluated through side by-side comparisons of photographs with either same grade or a one-grade difference. RESULTS: The scale demonstrated excellent reliability when used by trained physicians and other healthcare practitioners. Intra-rater agreement between the 2 live-subject rating sessions was nearly perfect. Substantial inter-rater agreement between the raters from both live sessions was also demonstrated. The mean absolute difference (95% confidence interval) in scale ratings was 1.08 (1.02, 1.14) for "clinically different" pairs and was 0.34 (0.27, 0.41) for "clinically same" pairs, suggesting a 1-point difference is clinically relevant. CONCLUSION: The Merz Infraorbital Hollow Assessment Scale is a validated, reliable, and clinically relevant photonumeric scale for rating infraorbital hollowing. The scale maintains its validity and reliability with reproducible results across a diverse group of males and females of various ages and Fitzpatrick Skin Types. J Drugs Dermatol. 2023;22(1):74-81.doi:10.36849/JDD.7191.

Subjects

MeSH terms (MEDLINE)

PhotographyMaleFemaleHumansReproducibility of ResultsObserver VariationSeverity of Illness IndexCheek

Cite

APA

Biesman, B., Verma, A., Cheng, N., & Duncan, A. (2023). Development and Validation of a Photonumeric Scale for Evaluation of Infraorbital Hollowing. Journal of Drugs in Dermatology. https://doi.org/10.36849/jdd.7191

Vancouver

Biesman B, Verma A, Cheng N, Duncan A. Development and Validation of a Photonumeric Scale for Evaluation of Infraorbital Hollowing. Journal of Drugs in Dermatology. 2023. doi:10.36849/jdd.7191

BibTeX
@article{Biesman2023,
  author = {Biesman, Brian and Verma, Amit and Cheng, Nuo and Duncan, Ashlee},
  title = {Development and Validation of a Photonumeric Scale for Evaluation of Infraorbital Hollowing},
  journal = {Journal of Drugs in Dermatology},
  year = {2023},
  doi = {10.36849/jdd.7191}
}
Start for free →