EUVIMEDEUVIMED entdecken
Crossref

Concordance Between Echocardiographic Left Ventricular Ejection Fraction by Simpson's Method, Global Longitudinal Strain, and Cardiac Magnetic Resonance

Álvaro Herrera-Escandón, Juan Pablo Morales-Grisales, Sebastián Ayala-Zapata, Stephany Barbosa-Balaguera, Álvaro José Muriel-Ruiz, Juan Felipe Bravo-Rueda, José Eduardo Citelli-Ramírez, Luis Fernando Osío-Jimenez, Luis Miguel Benitez-Gómez, Carlos Javier Ramírez-Estupiñán

ABC Imagem Cardiovascular · 25.06.2026 · 39 (2)

DOI: 10.36660/abcimg.20250102i ↗

Kurz gefasst

Fachartikel in der Zeitschrift ABC Imagem Cardiovascular, erschienen am 25.06.2026. Verfasst von Álvaro Herrera-Escandón und 9 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Left ventricular ejection fraction (LVEF) measured by echocardiography is a widely used parameter in clinical practice for the assessment of ventricular function. More recently, global longitudinal strain (GLS) has emerged as a complementary method, as has the assessment of LVEF by cardiac magnetic resonance (CMR). However, regional evidence evaluating the concordance among these three techniques remains limited.

Objectives

To assess the concordance between echocardiographic and CMR measurements in patients treated at a cardiovascular clinic in the city of Cali, Colombia.

Methods

This cross-sectional, analytical, descriptive study included 35 patients with confirmed or suspected heart disease, in whom all three methods were performed consecutively. Concordance was evaluated using Lin's concordance correlation coefficient (CCC), Bland-Altman plots for LVEF, and linear and quadratic weighted κ coefficients for agreement between LVEF classifications.

Results

The mean age was 58 years, and 60% of participants were male. The most common comorbidities were hypertension (22%) and dyslipidemia (11%). The mean LVEF was 59% by Simpson's method and 57.7% by CMR, while the mean GLS was −17.7%. Concordance was as follows: Simpson's LVEF vs. CMR (CCC, 0.831; 95%CI, 0.609-0.932); GLS vs. CMR-derived LVEF (CCC, 0.751; 95%CI, 0.419-0.903); and Simpson's LVEF vs. GLS (CCC, 0.891; 95%CI, 0.721-0.957).

Conclusions

Both Simpson's method and GLS are valid tools for estimating systolic function. CMR remains the reference standard.

Zitieren

APA

Herrera-Escandón, Á., Morales-Grisales, J. P., Ayala-Zapata, S., Barbosa-Balaguera, S., Muriel-Ruiz, Á. J., Bravo-Rueda, J. F., Citelli-Ramírez, J. E., Osío-Jimenez, L. F., Benitez-Gómez, L. M., & Ramírez-Estupiñán, C. J. (2026). Concordance Between Echocardiographic Left Ventricular Ejection Fraction by Simpson's Method, Global Longitudinal Strain, and Cardiac Magnetic Resonance. ABC Imagem Cardiovascular, 39(2). https://doi.org/10.36660/abcimg.20250102i

Vancouver

Herrera-Escandón Á, Morales-Grisales JP, Ayala-Zapata S, Barbosa-Balaguera S, Muriel-Ruiz ÁJ, Bravo-Rueda JF, et al. Concordance Between Echocardiographic Left Ventricular Ejection Fraction by Simpson's Method, Global Longitudinal Strain, and Cardiac Magnetic Resonance. ABC Imagem Cardiovascular. 2026;39(2). doi:10.36660/abcimg.20250102i

BibTeX
@article{HerreraEscandn2026,
  author = {Herrera-Escandón, Álvaro and Morales-Grisales, Juan Pablo and Ayala-Zapata, Sebastián and Barbosa-Balaguera, Stephany and Muriel-Ruiz, Álvaro José and Bravo-Rueda, Juan Felipe and Citelli-Ramírez, José Eduardo and Osío-Jimenez, Luis Fernando and Benitez-Gómez, Luis Miguel and Ramírez-Estupiñán, Carlos Javier},
  title = {Concordance Between Echocardiographic Left Ventricular Ejection Fraction by Simpson's Method, Global Longitudinal Strain, and Cardiac Magnetic Resonance},
  journal = {ABC Imagem Cardiovascular},
  year = {2026},
  volume = {39},
  number = {2},
  doi = {10.36660/abcimg.20250102i}
}
Kostenlos starten →