EUVIMEDEUVIMED entdecken
Crossref

Artificial intelligence based left ventricular ejection fraction and global longitudinal strain in cardiac amyloidosis

Juan I Cotella iD, Jeremy A Slivnick, Emily Sanderson, Cristiane Singulane, Jamie O'Driscoll, Federico M Asch, Karima Addetia iD, Gary Woodward, Roberto M Lang

Echocardiography · 2023-03 · 40 (3) · 188-195

DOI: 10.1111/echo.15516 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Echocardiography, online erschienen am 09.01.2023. Verfasst von Juan I Cotella und 8 weiteren Autor:innen. Beteiligte Einrichtung: University of Chicago Medical Center, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Amyloidosis, Ventricular Dysfunction, Left. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Assessment of left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) plays a key role in the diagnosis of cardiac amyloidosis (CA). However, manual measurements are time consuming and prone to variability. We aimed to assess whether fully automated artificial intelligence (AI) calculation of LVEF and GLS provide similar estimates and can identify abnormalities in agreement with conventional manual methods, in patients with pre‐clinical and clinical CA.

Methods

We identified 51 patients (age 80 ± 10 years, 53% male) with confirmed CA according to guidelines, who underwent echocardiography before and/or at the time of CA diagnosis (median (IQR) time between observations 3.87 (1.93, 5.44 years). LVEF and GLS were quantified from the apical 2‐ and 4‐chamber views using both manual and fully automated methods (EchoGo Core 2.0, Ultromics). Inter‐technique agreement was assessed using linear regression and Bland‐Altman analyses and two‐way ANOVA. The diagnostic accuracy and time for detecting abnormalities (defined as LVEF ≤ 50% and GLS ≥ −15.1%, respectively) using AI was assessed by comparisons to manual measurements as a reference.

Results

There were no significant differences in manual and automated LVEF and GLS values in either pre‐CA ( p = .791 and p = .105, respectively) or at diagnosis ( p = .463 and p = .722). The two methods showed strong correlation on both the pre‐CA ( r = .78 and r = .83) and CA echoes ( r = .74 and r = .80) for LVEF and GLS, respectively. The sensitivity and specificity of AI‐derived indices for detecting abnormal LVEF were 83% and 86%, respectively, in the pre‐CA echo and 70% and 79% at CA diagnosis. The sensitivity and specificity of AI‐derived indices for detecting abnormal GLS was 82% and 86% in the pre‐CA echo and 100% and 67% at the time of CA diagnosis. There was no significant difference in the relationship between LVEF ( p = .99) and GLS ( p = .19) and time to abnormality between the two methods.

Conclusion

Fully automated AI‐calculated LVEF and GLS are comparable to manual measurements in patients pre‐CA and at the time of CA diagnosis. The widespread implementation of automated LVEF and GLS may allow for more rapid assessment in different disease states with comparable accuracy and reproducibility to manual methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmyloidosisVentricular Dysfunction, LeftHumansMaleAgedAged, 80 and overFemaleVentricular Function, LeftStroke VolumeArtificial IntelligenceReproducibility of ResultsGlobal Longitudinal StrainPredictive Value of Tests

Stichwörter der Autor:innen

amyloidosisartificial intelligencedeep learningejection fractionglobal longitudinal strain

Autor:innen und Institutionen

  • University of Chicago Medical Center, Chicago, Illinois, USA.
  • Ultromics Ltd, 4630 Kingsgate, Cascade Way, Oxford Business Park South, Oxford, OX4 2SU, Oxford, UK.
  • Canterbury Christ Church University School of Psychology, Politics and Sociology, Canterbury, UK.
  • Department of Cardiology, St George's University Hospitals NHS Foundation Trust, Tooting, London, UK.
  • Cardiovascular Core Labs, MedStar Health Research Institute, Washington DC, Washington, USA.

ORCID-Profile: Juan I Cotella, Karima Addetia

Zitieren

APA

Cotella, J. I., Slivnick, J. A., Sanderson, E., Singulane, C., O'Driscoll, J., Asch, F. M., Addetia, K., Woodward, G., & Lang, R. M. (2023). Artificial intelligence based left ventricular ejection fraction and global longitudinal strain in cardiac amyloidosis. Echocardiography, 40(3), 188-195. https://doi.org/10.1111/echo.15516

Vancouver

Cotella JI, Slivnick JA, Sanderson E, Singulane C, O'Driscoll J, Asch FM, et al. Artificial intelligence based left ventricular ejection fraction and global longitudinal strain in cardiac amyloidosis. Echocardiography. 2023;40(3):188-195. doi:10.1111/echo.15516

BibTeX
@article{Cotella2023,
  author = {Cotella, Juan I and Slivnick, Jeremy A and Sanderson, Emily and Singulane, Cristiane and O'Driscoll, Jamie and Asch, Federico M and Addetia, Karima and Woodward, Gary and Lang, Roberto M},
  title = {Artificial intelligence based left ventricular ejection fraction and global longitudinal strain in cardiac amyloidosis},
  journal = {Echocardiography},
  year = {2023},
  volume = {40},
  number = {3},
  pages = {188--195},
  doi = {10.1111/echo.15516}
}
Kostenlos starten →