Optimal Local Impedance Parameters for Catheter Ablation of the Cavo-tricuspid Isthmus in Atrial Flutter Patients: A Retrospective Analysis
HCA Healthcare Journal of Medicine · 31.12.2025 · 6 (6)
DOI: 10.36518/2689-0216.2153 ↗Kurz gefasst
Fachartikel in der Zeitschrift HCA Healthcare Journal of Medicine, online erschienen am 31.12.2025. Verfasst von Yamann Sahlool und 4 weiteren Autor:innen. Beteiligte Einrichtung: Los Robles Regional Medical Center, Thousand Oaks, California. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Atrial flutter is a common arrhythmia, and catheter ablation offers a potentially curative intervention. However, there is a continued desire to enhance the procedure’s efficiency and safety to optimize patient outcomes. Recently, local impedance (LI) has garnered attention as a novel approach to optimizing ablation procedures. The parameters of LI change when associated with durable ablation lesions for cavo-tricuspid isthmus (CTI) which remains poorly defined. This study aims to address this gap through analysis of gathered data.
Methods
We conducted a retrospective data analysis of 121 consecutive patients who underwent local impedance-guided catheter ablation of the CTI for typical atrial flutter. The durability of the ablated lesions was assessed using high-resolution activation and voltage mapping to detect conduction gaps. The maximum LI drop was calculated for each ablation point. Each point was assessed by 3-dimensional electroanatomic mapping with binary categorization denoting either durable/successful ablation lesion or non-durable/unsuccessful ablation lesion. In addition, subjective evaluation of catheter-tissue contact was assessed by a single proceduralist using intracardiac echocardiography (ICE) and was then stratified as high-level contact, intermediate-level contact, and low-level contact. A total of 1814 ablation points were analyzed.
Results
The mean maximum drop in LI was significantly different (P < .0001) between the -16.38 ohms (95% confidence interval [CI], -17.54 to -15.23) for unsuccessful lesions and -20.79 ohms (95% CI, -21.20 to -20.38) for successful lesions. Among patients with at least 1 unsuccessful lesion, the maximum drop in LI was -16.38 for those that were unsuccessful in comparison to -19.81 for successful lesions (95% CI [-20.56, -19.06], P < .0001). The mean maximum drop in LI was progressively smaller moving from the high-level contact group (-25.93 ± 9.35), to the intermediate-level contact group (-19.04 ± 7.64), and again for the low-level contact group (-13.84 ± 6.93).
Conclusion
Our results give insight into the relationship between maximal local impedance change and the achievement of a durable block along the CTI.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Los Robles Regional Medical Center, Thousand Oaks, California.
Zitieren
APA
Sahlool, Y., Dacquay, Y., Avedikian, S., Kim, J. H. J., & Sovari, A. (2025). Optimal Local Impedance Parameters for Catheter Ablation of the Cavo-tricuspid Isthmus in Atrial Flutter Patients: A Retrospective Analysis. HCA Healthcare Journal of Medicine, 6(6). https://doi.org/10.36518/2689-0216.2153
Vancouver
Sahlool Y, Dacquay Y, Avedikian S, Kim JHJ, Sovari A. Optimal Local Impedance Parameters for Catheter Ablation of the Cavo-tricuspid Isthmus in Atrial Flutter Patients: A Retrospective Analysis. HCA Healthcare Journal of Medicine. 2025;6(6). doi:10.36518/2689-0216.2153
BibTeX
@article{Sahlool2025,
author = {Sahlool, Yamann and Dacquay, Yann and Avedikian, Saro and Kim, Jeong Hwan J and Sovari, Ali},
title = {Optimal Local Impedance Parameters for Catheter Ablation of the Cavo-tricuspid Isthmus in Atrial Flutter Patients: A Retrospective Analysis},
journal = {HCA Healthcare Journal of Medicine},
year = {2025},
volume = {6},
number = {6},
doi = {10.36518/2689-0216.2153}
}
EUVIMED