Right Atrial Dimension Is Related to Bidirectional Block Parameters After Cavotricuspid Isthmus Ablation in Patients with Typical Atrial Flutter
Journal of Clinical Medicine · 22.05.2026 · 15 (11) · 4008
DOI: 10.3390/jcm15114008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 22.05.2026. Verfasst von Mustafa Lutfullah Ardıc und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University of Health Sciences, Adana Health Practice and Research Center, 01230 Adana, Turkey. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
There is insufficient data in the literature regarding the relationship between bidirectional conduction block (BCB) parameters and right atrial dimension (RAd). In our study, we aimed to evaluate the relationship between RAd and BCB parameters in typical atrial flutter (AFL) patients.
Methods
This prospective study included 197 patients who underwent successful RFA with a diagnosis of typical AFL between 2020 and 2025. We performed RAd and BCB measurements in addition to routine assessments in all patients. The presence of BCB was confirmed by measurement of the CTI double-potential peak-to-peak interval (DPPPI) during CSp pacing, as well as by the difference between the conduction times from isthmus lateral-to-medial pacing to the CSp stimulus (ΔI-CS = LI-to-CSp − MI-to-CSp) and the difference between the conduction times from CSp pacing to the lateral and medial isthmus sites (ΔCS-I = CSp-to-LI − CSp-to-MI). Patients were divided into 3 groups according to RAd: Group-I: 2.4 cm/m2.
Results
The number of patients in Groups I, II, and III was determined to be 99, 55, and 43, respectively. RA-volume, LVEF, RAd, and LAd values, as well as LI-to-CSp, ΔI-CS, CSp-to-LI, ΔCS-I, and DPPPI durations, significantly increased from Group I to Group III. MI-to-CSp and CSp-to-MI durations also increased from Group I to Group III; being Group I was significantly lower than Groups II and III. When DPPPI durations were categorized as ≤110 ms, 110–119 ms, 120–129 ms, and ≥130 ms, a significant difference was observed among the groups, and all Group II–III cases were found to have a DPPPI duration of ≥120 ms. In Groups II and III, the proportions of patients with DPPPI ≥ 130 ms were 46% and 84%, respectively.
Conclusions
Our study showed that cavotricuspid-isthmus BCB parameters, which are indicators of successful AFL ablation, are closely and significantly related to RAd.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University of Health Sciences, Adana Health Practice and Research Center, 01230 Adana, Turkey.
- Department of Internal Medicine, University of Health Sciences, Adana Health Practice and Research Center, 01230 Adana, Turkey.
- Department of Cardiology, Cukurova State Hospital, 01170 Adana, Turkey.
ORCID-Profile: Mustafa Lutfullah Ardıc, Hilmi Erdem Sumbul, Fadime Koca, Mevlut Koc
Zitieren
APA
Ardıc, M. L., Sezici, E., Sumbul, H. E., Koca, F., & Koc, M. (2026). Right Atrial Dimension Is Related to Bidirectional Block Parameters After Cavotricuspid Isthmus Ablation in Patients with Typical Atrial Flutter. Journal of Clinical Medicine, 15(11), 4008. https://doi.org/10.3390/jcm15114008
Vancouver
Ardıc ML, Sezici E, Sumbul HE, Koca F, Koc M. Right Atrial Dimension Is Related to Bidirectional Block Parameters After Cavotricuspid Isthmus Ablation in Patients with Typical Atrial Flutter. Journal of Clinical Medicine. 2026;15(11):4008. doi:10.3390/jcm15114008
BibTeX
@article{Ardc2026,
author = {Ardıc, Mustafa Lutfullah and Sezici, Emre and Sumbul, Hilmi Erdem and Koca, Fadime and Koc, Mevlut},
title = {Right Atrial Dimension Is Related to Bidirectional Block Parameters After Cavotricuspid Isthmus Ablation in Patients with Typical Atrial Flutter},
journal = {Journal of Clinical Medicine},
year = {2026},
volume = {15},
number = {11},
pages = {4008},
doi = {10.3390/jcm15114008}
}
EUVIMED