EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bowtie and spectral filtration in CT for radiographic practice

Davide Festa, Antonino Martino, Daniele Costarella, Rita Carmela Nocera, Giorgio Coppola, Ivan Calabrò, Giuseppe Scappatura, Francesca Barillà, Antonino Borzumati

Journal of Advanced Health Care · 24.10.2026 · 8 (4)

DOI: 10.36017/jahc202684644 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Advanced Health Care, online erschienen am 24.10.2026. Verfasst von Davide Festa und 8 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This review connects CT bowtie and spectral filtration with radiographic practice through a common framework linking patient geometry, exposure control, dose endpoints and task-specific image performance. A targeted narrative synthesis combined web and Europe PMC searches with reference follow-up. Evidence was compared by mechanism, study design, comparator and endpoint, without pooling or formal risk-of-bias assessment. The synthesis identified two interacting pathways through which off-centring affects exposure: mismatch between patient geometry and the bowtie-shaped beam, and changes in localiser information used by automatic exposure control. Scanner and endpoint differences prevent a universal off-centring penalty. Camera assistance can improve positioning or workflow without consistent downstream dose benefits. Spectral filtration changes attenuation and dose-conversion relationships, requiring task-specific assessment. Photon-counting studies identify additional calibration and scatter-correction requirements; adaptive attenuators remain a research perspective. Centring should be judged against the intended anatomical target and scanner protocol. Positioning accuracy, scanner dose indices, organ dose and diagnostic performance are distinct outcomes that do not necessarily improve together. Interpreting them together offers a more defensible basis for practice than applying a universal off-centring penalty. Radiographers should assess camera recommendations against the intended anatomy and localiser geometry. Protocol changes affecting quantitative CT require joint validation with radiologists and medical physicists. Local audits should examine positioning, dose and image quality separately.

Zitieren

APA

Festa, D., Martino, A., Costarella, D., Nocera, R. C., Coppola, G., Calabrò, I., Scappatura, G., Barillà, F., & Borzumati, A. (2026). Bowtie and spectral filtration in CT for radiographic practice. Journal of Advanced Health Care, 8(4). https://doi.org/10.36017/jahc202684644

Vancouver

Festa D, Martino A, Costarella D, Nocera RC, Coppola G, Calabrò I, et al. Bowtie and spectral filtration in CT for radiographic practice. Journal of Advanced Health Care. 2026;8(4). doi:10.36017/jahc202684644

BibTeX
@article{Festa2026,
  author = {Festa, Davide and Martino, Antonino and Costarella, Daniele and Nocera, Rita Carmela and Coppola, Giorgio and Calabrò, Ivan and Scappatura, Giuseppe and Barillà, Francesca and Borzumati, Antonino},
  title = {Bowtie and spectral filtration in CT for radiographic practice},
  journal = {Journal of Advanced Health Care},
  year = {2026},
  volume = {8},
  number = {4},
  doi = {10.36017/jahc202684644}
}
Kostenlos starten →