EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System

Indah Firdausi Nuzula, Priyambada Cahya Nugraha, Moch Prastawa Assalim Tetra Putra, I Dewa Gede Hari Wisana, Riqqah Dewiningrum, Alfi Nur Zeha, Syaifullah Yusuf

Jurnal Teknokes · 18.06.2026 · 19 (2) · 101-109

DOI: 10.35882/jteknokes.v19i2.152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Jurnal Teknokes, online erschienen am 18.06.2026. Verfasst von Indah Firdausi Nuzula und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

SpO₂ is a critical physiological parameter in vital sign monitoring, particularly within Internet of Things (IoT) based healthcare systems that enable continuous and remote patient observation. However, the accuracy of SpO₂ measurements is often compromised by motion artifacts in photoplethysmograph (PPG) signals, which introduce amplitude distortion and frequency spreading that degrade oxygen saturation estimation. Although various signal processing approaches have been proposed, limited studies have evaluated digital filtering performance on real PPG signals using real-time embedded platforms with direct comparison of filter characteristics. This study aims to analyze the effectiveness of two Infinite Impulse Response (IIR) digital filters, Butterworth and Elliptic, in suppressing motion artifacts in SpO₂ signals processed on a microcontroller. Data were collected from ten healthy participants under three conditions: baseline (no movement), induced finger motion, and filtered signals. Signal quality improvement was assessed using Fast Fourier Transform (FFT), Power Spectral Density (PSD), and Signal-to-Noise Ratio (SNR) analyses. Results indicate that motion artifacts increase high-frequency components above 3 Hz and disrupt the morphological integrity of the PPG waveform. Applying a low-pass IIR filter with a 3 Hz cutoff frequency successfully restored the principal periodic components. The Butterworth filter produced a smoother spectral response with minimal phase distortion, while the Elliptic filter achieved a sharper roll-off with slight passband ripple. Quantitative evaluation demonstrated average SNR improvements of +0.905 dB (Butterworth) and +0.899 dB (Elliptic) using FFT , and +0.98 dB and +0.66 dB, respectively, using PSD. These findings demonstrate that computationally efficient IIR filtering can be reliably implemented in resource-constrained embedded platforms without compromising signal integrity. This approach enhances signal stability, reduces false desaturation alarms, supports scalable deployment in wearable and telemedicine applications, improving patient safety and system robustness in continuous remote health monitoring.

Zitieren

APA

Nuzula, I. F., Nugraha, P. C., Putra, M. P. A. T., Wisana, I. D. G. H., Dewiningrum, R., Zeha, A. N., & Yusuf, S. (2026). Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System. Jurnal Teknokes, 19(2), 101-109. https://doi.org/10.35882/jteknokes.v19i2.152

Vancouver

Nuzula IF, Nugraha PC, Putra MPAT, Wisana IDGH, Dewiningrum R, Zeha AN, et al. Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System. Jurnal Teknokes. 2026;19(2):101-109. doi:10.35882/jteknokes.v19i2.152

BibTeX
@article{Nuzula2026,
  author = {Nuzula, Indah Firdausi and Nugraha, Priyambada Cahya and Putra, Moch Prastawa Assalim Tetra and Wisana, I Dewa Gede Hari and Dewiningrum, Riqqah and Zeha, Alfi Nur and Yusuf, Syaifullah},
  title = {Robust Real-Time SpO₂ Signal Enhancement Using Optimized IIR Filtering in a Web-Based Vital Sign Monitoring System},
  journal = {Jurnal Teknokes},
  year = {2026},
  volume = {19},
  number = {2},
  pages = {101--109},
  doi = {10.35882/jteknokes.v19i2.152}
}
Kostenlos starten →