EUVIMEDEUVIMED entdecken
Crossref

Robust Vital Sign Monitoring via Condition-Aware Spatial Filtering and Adaptive Time–Frequency Decomposition

Wei Guo, Mu Li

IEEE Sensors Journal · 01.07.2026 · 26 (13) · 20372-20384

DOI: 10.1109/jsen.2026.3693879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.07.2026. Verfasst von Wei Guo und 1 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Development and Implementation of a Non-Contact Vital Sign Monitoring System for Wounded Personnel.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Robust noncontact vital sign monitoring in dynamic environments remains a formidable challenge, primarily because of the masking effects of random body motion (RBM) and the spectral overlap of motion harmonics. However, conventional time–frequency decomposition methods fundamentally rely on quasistationary assumptions, leading to severe mode mixing and tracking failure when highly dynamic RBM and respiratory harmonics overlap in the spectral domain. Addressing this critical limitation in separating physiological signals from nonstationary clutter, this study presents a condition-aware spatiotemporal processing framework. Building upon a sequential pipeline, the proposed method introduces a highly synergistic framework where the spatial filtering stage is specifically optimized to provide a robust, impulse-free input for the subsequent adaptive time–frequency analysis. Technically, a condition-number-aware minimum variance distortionless response (MVDR) beamformer enhanced by the median absolute deviation (MAD) is introduced to ensure spatial robustness against impulsive motion outliers. Furthermore, an optimized Hilbert vibration decomposition (HVD) algorithm is proposed, featuring a physiological-band-driven notch filter that preemptively suppresses harmonic interference before frequency extraction. Experimental evaluations were conducted using both high-fidelity simulations and real-world scenarios. Results indicate a promising performance improvement: in physical experiments with significant body swaying, the proposed framework achieves a heart rate (HR) estimation RMSE of 4.14 BPM, corresponding to an 83.7% error reduction compared to standard FFT baselines. Even under simulated extreme interference, the method maintained a mean absolute error (MAE) of 0.0312 Hz, verifying its robustness and capability to deliver high-fidelity tracking for contactless health monitoring in dynamic environments.

Förderung

  • Development and Implementation of a Non-Contact Vital Sign Monitoring System for Wounded Personnel

Zitieren

APA

Guo, W., & Li, M. (2026). Robust Vital Sign Monitoring via Condition-Aware Spatial Filtering and Adaptive Time–Frequency Decomposition. IEEE Sensors Journal, 26(13), 20372-20384. https://doi.org/10.1109/jsen.2026.3693879

Vancouver

Guo W, Li M. Robust Vital Sign Monitoring via Condition-Aware Spatial Filtering and Adaptive Time–Frequency Decomposition. IEEE Sensors Journal. 2026;26(13):20372-20384. doi:10.1109/jsen.2026.3693879

BibTeX
@article{Guo2026,
  author = {Guo, Wei and Li, Mu},
  title = {Robust Vital Sign Monitoring via Condition-Aware Spatial Filtering and Adaptive Time–Frequency Decomposition},
  journal = {IEEE Sensors Journal},
  year = {2026},
  volume = {26},
  number = {13},
  pages = {20372--20384},
  doi = {10.1109/jsen.2026.3693879}
}
Kostenlos starten →