EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Hybrid Time-Frequency ECG Arrhythmia Classification with Feature-Model Compatibility and Ensemble Decision Fusion

J Prayoga, Melinda Melinda, Teuku Yuliar Arif, Herlina Dimiati

Journal of Electronics, Electromedical Engineering, and Medical Informatics · 30.07.2026 · 8 (3) · 1277-1295

DOI: 10.35882/jeeemi.v8i3.1730 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electronics, Electromedical Engineering, and Medical Informatics, online erschienen am 30.07.2026. Verfasst von J Prayoga und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac arrhythmia is a critical cardiovascular disorder associated with high global mortality, while electrocardiogram (ECG)-based diagnosis remains time-consuming and susceptible to inter-observer variability. Although recent artificial intelligence approaches have improved automated ECG analysis, many existing studies rely on single time-frequency representations and uniform classification strategies, limiting their ability to capture complementary ECG characteristics. This study proposed a hybrid time-frequency ECG arrhythmia classification framework incorporating feature–model compatibility and ensemble decision fusion to improve classification robustness and reliability. ECG signals from the MIT-BIH Arrhythmia Database were preprocessed using a fourth-order Butterworth bandpass filter and segmented using overlapping windows. To prevent data leakage, patient-wise cross-validation was employed, ensuring that ECG segments originating from the same patient were assigned exclusively to either training or testing folds. Three complementary time-frequency representations, namely Mel-Spectrogram, Short-Time Fourier Transform (STFT), and Discrete Wavelet Transform (DWT), were paired with their most compatible classifiers: Convolutional Neural Network (CNN); Random Forest (RF); and Support Vector Machine (SVM); respectively. Decision fusion was performed using stacking, hard voting, and soft voting strategies. Experimental results showed that the DWT-SVM model with stacking achieved the best overall performance, attaining 94.82% accuracy and a 94.59% F1-score, while STFT-RF with hard voting achieved comparable performance with 94.75% accuracy and a 94.50% F1-score. In contrast, Mel-Spectrogram-CNN produced substantially lower performance with 81.45% accuracy, indicating limited suitability of Mel-scale representations for ECG morphology analysis. Statistical analysis confirmed significant performance differences among models (p < 0.001). The findings demonstrate that integrating hybrid time-frequency representations with feature–model compatibility and model-dependent decision fusion provides a robust framework for automated ECG arrhythmia classification with strong potential for clinical decision support and real-time cardiac monitoring applications

Zitieren

APA

Prayoga, J., Melinda, M., Arif, T. Y., & Dimiati, H. (2026). Hybrid Time-Frequency ECG Arrhythmia Classification with Feature-Model Compatibility and Ensemble Decision Fusion. Journal of Electronics, Electromedical Engineering, and Medical Informatics, 8(3), 1277-1295. https://doi.org/10.35882/jeeemi.v8i3.1730

Vancouver

Prayoga J, Melinda M, Arif TY, Dimiati H. Hybrid Time-Frequency ECG Arrhythmia Classification with Feature-Model Compatibility and Ensemble Decision Fusion. Journal of Electronics, Electromedical Engineering, and Medical Informatics. 2026;8(3):1277-1295. doi:10.35882/jeeemi.v8i3.1730

BibTeX
@article{Prayoga2026,
  author = {Prayoga, J and Melinda, Melinda and Arif, Teuku Yuliar and Dimiati, Herlina},
  title = {Hybrid Time-Frequency ECG Arrhythmia Classification with Feature-Model Compatibility and Ensemble Decision Fusion},
  journal = {Journal of Electronics, Electromedical Engineering, and Medical Informatics},
  year = {2026},
  volume = {8},
  number = {3},
  pages = {1277--1295},
  doi = {10.35882/jeeemi.v8i3.1730}
}
Kostenlos starten →