EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

HAT ‐ ECG : Hybrid autoencoder‐transformer architecture for ECG arrhythmia classification

Shahin Sharbaf Movassaghpour iD, Masoud Kargar iD, Ali Bayani iD

Physiological Reports · 2026-06 · 14 (12)

DOI: 10.14814/phy2.70990 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Reports, online erschienen am 23.06.2026. Verfasst von Shahin Sharbaf Movassaghpour und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Engineering, Ta.C., Islamic Azad University, Tabriz, Iran. Hauptthemen laut MEDLINE: Arrhythmias, Cardiac, Electrocardiography, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate and efficient analysis of electrocardiogram (ECG) signals is essential for early detection of cardiac arrhythmias. However, many deep learning models suffer from limited generalization to unseen patients, reduced interpretability, and high computational demands. To address these challenges, we propose HAT‐ECG, a hybrid Autoencoder‐Transformer architecture that integrates unsupervised feature learning with attention‐based temporal modeling. The convolutional autoencoder extracts compact, noise‐robust latent representations of ECG beats, while the Transformer's Multi‐Head Attention mechanism adaptively focuses on diagnostically relevant waveform segments. The model was evaluated on three public datasets: MIT‐BIH, INCART, and the independent PTB Diagnostic ECG Dataset (290 subjects, entirely outside the original datasets). Under standard beat‐wise splitting for benchmarking, HAT‐ECG achieved state‐of‐the‐art accuracies of 99.91% (MIT‐BIH 5‐class), 99.69% (MIT‐BIH AAMI), 99.15% (INCART 3‐class AAMI), and 98.45% (PTB 2‐class). Critically, under strict patient‐wise splitting on MIT‐BIH (completely disjoint training and test patients), the model maintained a realistic accuracy of 90.81% (F1‐score 92.61%), with strong generalization to new patients. With only 0.021 GFLOPs, HAT‐ECG offers an excellent balance of high performance, interpretability, and efficiency, making it highly suitable for real‐time wearable and edge‐device cardiac monitoring. This work advances deep learning for intelligent and deployable arrhythmia classification by combining accuracy, cross‐patient generalization, and computational minimalism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arrhythmias, CardiacElectrocardiographySignal Processing, Computer-AssistedHumansAutoencoder

Stichwörter der Autor:innen

autoencoderbiomedical signal processingelectrocardiogram arrhythmia classificationimbalanced datapatient‐wise evaluationtransformerwearable monitoring

Autor:innen und Institutionen

  • Department of Computer Engineering, Ta.C., Islamic Azad University, Tabriz, Iran.

ORCID-Profile: Shahin Sharbaf Movassaghpour, Masoud Kargar, Ali Bayani

Zitieren

APA

Sharbaf Movassaghpour, S., Kargar, M., & Bayani, A. (2026). HAT ‐ ECG : Hybrid autoencoder‐transformer architecture for ECG arrhythmia classification. Physiological Reports, 14(12). https://doi.org/10.14814/phy2.70990

Vancouver

Sharbaf Movassaghpour S, Kargar M, Bayani A. HAT ‐ ECG : Hybrid autoencoder‐transformer architecture for ECG arrhythmia classification. Physiological Reports. 2026;14(12). doi:10.14814/phy2.70990

BibTeX
@article{SharbafMovassaghpour2026,
  author = {Sharbaf Movassaghpour, Shahin and Kargar, Masoud and Bayani, Ali},
  title = {HAT ‐ ECG : Hybrid autoencoder‐transformer architecture for ECG arrhythmia classification},
  journal = {Physiological Reports},
  year = {2026},
  volume = {14},
  number = {12},
  doi = {10.14814/phy2.70990}
}
Kostenlos starten →