Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization

Nurul Al Istigho Farola, Her Gumiwang, Sumber Sumber

International Journal of Advanced Health Science and Technology · 2021

DOI: 10.35882/ijahst.v1i1.5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Advanced Health Science and Technology, 2021. Verfasst von Nurul Al Istigho Farola und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measuring the temperature on the dry sterilizer is very necessary because the temperature inside the dry sterilizer has the possibility that the temperature is not the same as the temperature that has been set and is displayed on the display. If the temperature in the dry sterilizer does not match the standard setting temperature for the sterilization process, then the sterilization process is said to be imperfect The purpose of this study is to record and monitor whether the distributed temperature in the sterilization chamber corresponds to the setting temperature. The workings of the temperature data logger tool is that the type K thermocouple temperature sensor will detect the temperature which then enters the analog signal conditioning circuit which then enters the ATMegga 2560 which has been given a program and processed in such a way, then the temperature will be displayed on a 4x20 character LCD. Temperature measurement data will be saved to the SD Card every 10 seconds in the form of a TXT file. This research has been used to record 2 sterilizers and compared with the Madgetech OctTemp2000 data logger. Based on data measurements and comparisons, the average error was obtained at a temperature of 50ºC with the smallest error value of 0.7% and the largest value of 3.9%. At a temperature of 100ºC, the smallest error value is 1.6% and the largest is 10.5%. Then at a temperature of 120ºC the smallest error value is 0.0% and the largest is 8.5%. This research can be used to help analyze the distribution of temperature in a room. With these measurement results, it can be said that this study still has afairly high error value at several measurement points.

Zitieren

APA

Farola, N. A. I., Gumiwang, H., & Sumber, S. (2021). Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization. International Journal of Advanced Health Science and Technology. https://doi.org/10.35882/ijahst.v1i1.5

Vancouver

Farola NAI, Gumiwang H, Sumber S. Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization. International Journal of Advanced Health Science and Technology. 2021. doi:10.35882/ijahst.v1i1.5

BibTeX
@article{Farola2021,
  author = {Farola, Nurul Al Istigho and Gumiwang, Her and Sumber, Sumber},
  title = {Nine Channel Temperature Data Logger in Measuring the Effectiveness of the Sterilization Process of Medical Instruments with Dry Sterilization},
  journal = {International Journal of Advanced Health Science and Technology},
  year = {2021},
  doi = {10.35882/ijahst.v1i1.5}
}
Kostenlos starten →